Comparison between thoracoscopic pleural cryobiopsy and conventional forceps biopsy in diagnosis of exudative pleural effusion: Assiut University experience

Author:

El-Morshedy Reham M1,El-kholy Maha M1,Kamel Nermeen A M H2,Sadek Samiaa H1,Abdel Ghany Alaa S1,Mohamed Marwan N1

Affiliation:

1. Department of Chest Diseases and Tuberculosis, Faculty of Medicine, Assiut University, Assiut, Egypt

2. Department of Pathology, Faculty of Medicine, Assiut University, Assiut, Egypt

Abstract

Abstract Context Exudative pleural effusion is a diagnostic dilemma that includes many steps; one of them is obtaining a definite diagnosis through pleural biopsy. Cryoprobes are being increasingly used for obtaining larger specimens with fewer crush artifacts. However, the safety and feasibility of cryoprobe biopsy compared with standard forceps for pleural biopsy have not been fully assessed. Aims To evaluate the diagnostic value, size, and quality of the specimens obtained by flexible cryoprobe in comparison with those obtained by flexible forceps probe during medical thoracoscopy in patients with exudative pleural effusion and to assess the possible complications from the procedure. Settings and design This interventional prospective study was carried out at the endoscopy unit at Chest Department and Tuberculosis Assiut University Hospital. Patients and methods This study included 60 patients with undiagnosed exudative pleural effusion. Medical thoracoscopy was carried out for all the patients, and pleural biopsies were taken from the parietal pleura using a conventional rigid forceps probe and flexible cryoprobe in the same settings. Results Cryoprobe biopsy established a definite diagnosis in 55/60, with 91.6% diagnostic yield, whereas forceps biopsy had a definite diagnosis in 53/60, with 88.3% diagnostic yield. The size of cryoprobe biopsy was significantly larger in comparison with the forceps biopsy (26.56 ± 22.16 vs. 17.38 ± 12.08 mm2; P<0.001). The depth of pleural biopsy was evaluated by the presence of extrapleural fat cells, which were significantly higher in cryoprobe biopsy in comparison with forceps biopsy [21 (35%) vs. 11 (18.3%); P=0.03]. There were no significant complications or procedure-related deaths. Conclusions Cryobiopsy is a possible safe and effective alternative to conventional forceps probe biopsy in the diagnosis of exudative pleural effusion with a larger, deeper, and less number of biopsies. It was also found that cryoprobe biopsy had a better diagnostic yield, sensitivity, and accuracy.

Publisher

Medknow

Subject

General Medicine

Reference16 articles.

1. Medical thoracoscopy versus image-guided pleural biopsy for diagnosing pleural diseases;Ibrahim;Egypt J Chest Dis Tuberc,2018

2. Safety and feasibility of pleural cryobiopsy compared to forceps biopsy during semi-rigid pleuroscopy;Pathak;Lung,2017

3. Pleural procedures and thoracic ultrasound: British Thoracic Society Pleural Disease Guideline 2010;Havelock;Thorax,2010

4. Medical thoracoscopy/pleuroscopy: step by step;Loddenkemper;Breathe,2011

5. Assessment by Mair scoring system for the cytodiagnostic preparations of conventional centrifuge and cytospin for body fluids;Sain;Ann Rom Soc Cell Biol,2021

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3