Comparison of dental force applied during endotracheal intubation with hyper-angulated and macintosh-type video laryngoscopy blades used by emergency medicine trainees: A randomized cross-over manikin study

Author:

Karabacak Ali Rıza1ORCID,Özturan İbrahim Ulaş12ORCID,Şefoğlu Ömer Faruk1ORCID,Doğan Nurettin Özgür1ORCID,Yaka Elif1ORCID,Yılmaz Serkan1ORCID,Pekdemir Murat1ORCID

Affiliation:

1. Department of Emergency Medicine, Faculty of Medicine, Kocaeli University, Kocaeli, Türkiye

2. Department of Medical Education, Institute of Health Sciences, Acibadem University, Istanbul, Türkiye

Abstract

Abstract OBJECTIVES: This study aimed to compare the effects of Macintosh-type and hyperangulated video laryngoscopy (VL) blades on dental force during endotracheal intubation (ETI) using Glidescope and McGrath VL devices. METHODS: In this randomized, crossover, manikin study conducted at a university emergency medicine (EM) program, 65 EM trainees included interns and residents performed 520 intubations using four different VL blades (GlideScope VL with Macintosh-type Mac T3 and hyperangular Lo Pro T3 blades and McGrath VL Macintosh-type MAC 4 and hyperangular McGrath X3 blades) in normal and difficult airway scenarios. The primary outcome of this study was the dental pressure (Newton) exerted during ETI. The secondary outcomes included c-spine motion (degree), intubation success (%), duration (seconds), successful glottic view (%), and intubator comfort (7-point Likert). RESULTS: Significant differences were observed in dental force (H(3) = 11.7, P = 0.008), c-spine motion (H(3) = 8.34, P = 0.039), duration (H(3) = 16.56, P = 0.001), and comfort (H(3) = 174.96, P < 0.001) across blade types. Glidescope LoPro T3 provided a significant lower dental force (adjusted P = 0.01), less c-spine motion (adjusted P = 0.031), and shorter intubation duration (adj P < 0.01) than the McGrath Mac 4. First attempt success and intubator comfort were significantly better with all Glidescope blades (z score of 3.7 and 4.7) than with McGrath blades (z score of-4.1 and-4.4). CONCLUSION: The Glidescope LoPro T3 blade demonstrated advantages in dental force, c-spine motion, and intubation duration compared with McGrath Mac 4. Overall, the Glidescope blades provided superior comfort and higher first attempt success rates.

Publisher

Medknow

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3