Artifacts in cranial MRI caused by extracranial foreign bodies and analysis of these foreign bodies

Author:

Kayaci Selim1,Tabak Ahmet2,Durur-Subasi Irmak3,Eldes Tugba4,Koksal Vaner5,Sirin Murat6,Arslan Yusuf Kemal7

Affiliation:

1. Departments of Neurosurgery, Faculty of Medicine, Erzincan University, Erzincan

2. Department of Radiology, Dışkapı Training and Research Hospital, Ankara, Turkey

3. Department of Chemistry, Faculty of Arts and Sciences, Sinop University

4. Departments of Radiology, Faculty of Medicine, Recep Tayyip Erdogan University

5. Departments of Neurosurgery, Faculty of Medicine, Recep Tayyip Erdogan University

6. Department of Physics, Faculty of Arts and Sciences, Recep Tayyip Erdogan University, Rize

7. Departments of Biostatistics, Faculty of Medicine, Erzincan University, Erzincan

Abstract

Abstract Purpose: The purpose of our study was to conduct a chemical analysis of extracranial foreign bodies (FBs) causing artifacts in cranial magnetic resonance imaging (MRI) and to investigate the association between chemical composition, magnetic susceptibility, and artifact size. Materials and Methods: A total of 12 patients were included in the study. The FBs responsible for the artifacts were visualized using cranial computed tomography (CT). Artifact-causing FBs were removed from the scalps of 10 patients and analyzed using scanning electron microscope with energy dispersive spectroscopy (SEM-EDS), X-ray diffraction spectroscopy (X-RD), and Fourier-transform infrared spectroscopy (FT-IR). The magnetic susceptibility of the samples was determined using the reference standard material MnCl2.6H2O. The volume of the MRI artifacts was measured in cubic centimeters (cm3). Results: EDS results demonstrated that the mean Fe ratio was 5.82% in the stone samples and 0.08% in the glass samples. Although no phase peaks were detected in the X-RD spectra of the glass samples, peaks of Fe2O3, Al2Ca (SiO4) were detected in the X-RD spectra of the stone samples. The FT-IR spectra revealed metal oxide peaks corresponding to Fe, Al, in the stone samples and peaks confirming Al2SiO5and Na2SiO3structures in the glass samples. The mean volumes of the MRI artifacts produced by the stone and glass samples were 5.9 cm3 and 2.5 cm3, respectively. Conclusions: Artifacts caused by extracranial FBs containing metal/metal oxide components are directly associated with their chemical composition and the artifact size are also related to element composition and magnetic susceptibility.

Publisher

Georg Thieme Verlag KG

Subject

Radiology, Nuclear Medicine and imaging

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3