Safety of a Novel Capsular Closure Device in Hip Arthroscopy for Femoroacetabular Impingement

Author:

Turcotte Justin J.1,Baxter Samantha N.1,Brennan Jane C.1,Johnson Andrea H.1,Petre Benjamin M.1

Affiliation:

1. Department of Orthopedics, Luminis Health Anne Arundel Medical Center, Maryland, USA

Abstract

Abstract Introduction: The utilization of hip arthroscopy for the management of femoroacetabular impingement has increased. Capsular closure has been shown to maintain biomechanical stability postoperatively compared to unrepaired capsules. The novel Cap-Fix device (Smith and Nephew, Watford, UK) was developed to aid in capsular closure both by improving the placement of suture and decreasing the number of steps required for capsulotomy. This study aimed to evaluate the safety of the Cap-Fix device for use in capsulotomy and capsular repair following hip arthroscopy. Materials and Methods: A retrospective review of 30 patients undergoing hip arthroscopy for the treatment of femoroacetabular impingement (FAI) with capsular repair using the Cap-Fix 45° or 70° Suture Passer was performed. The Hip Disability and Osteoarthritis Outcome Score for Joint Replacement (HOOS JR) and Patient-Reported Outcomes Measurement Information System-Physical Function (PROMIS-PF) measures were used to evaluate patient-reported outcomes at the baseline and the follow-up intervals. Outcomes of interest included complications and patient-reported outcomes at 2-week, 6-week, and 3-month follow-up. Results: All patients completed 2- and 6-week follow-up, and 28 (93.3%) completed 3-month follow-up. Two patients experienced complications; one with pain requiring glucocorticoid injection at 6 weeks postoperatively, and another with a 12-mm capsular defect found on 3-month postoperative magnetic resonance imaging requiring repeat arthroscopic debridement, revision labral repair, and capsular plication. By 3 months postoperatively, statistically significant improvement in HOOS JR but not PROMIS-PF scores was seen. Conclusion: The Cap-Fix device appears to be safe for use in capsulotomy and subsequent capsular repair during hip arthroscopy for FAI.

Publisher

Medknow

Reference25 articles.

1. Femoroacetabular impingement;Bedi;J Bone Joint Surg Am,2013

2. Trends in hip arthroscopy utilization in the United States;Bozic;J Arthroplasty,2013

3. Gross instability after hip arthroscopy:An analysis of case reports evaluating surgical and patient factors;Yeung;Arthroscopy,2016

4. Routine interportal capsular repair does not lead to superior clinical outcome following arthroscopic femoroacetabular impingement correction with labral repair;Filan;Arthroscopy,2020

5. Treatment of femoroacetabular impingement:Labrum, cartilage, osseous deformity, and capsule;Philippon;Am J Orthop (Belle Mead NJ),2017

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3