A novel method for blood volume estimation using trivalent chromium in rabbit models

Author:

Baby Prathap Moothamadathil1,Kumar Pramod2,Kumar Rajesh3,Jacob Sanu S.4,Rawat Dinesh5,Binu V. S.6,Karun Kalesh M.6

Affiliation:

1. Department of Physiology, Melaka Manipal Medical College, Manipal campus, Manipal University, Karnataka, India

2. Department of Plastic Surgery, King Abdul Aziz Specialist Hospital, Al Jouf, Saudi Arabia

3. Department of Nuclear Medicine, Kasturba Medical College, Manipal, Manipal University, Karnataka, India

4. Department of Physiology, Kasturba Medical College, Manipal, Manipal University, Karnataka, India

5. Department of Nuclear Medicine, Post Graduate Institute of Medical Education and Research, Chandigarh, India,

6. Department of Statistics, Manipal Univeristy, Manipal, Karnataka, India

Abstract

ABSTRACT Background: Blood volume measurement though important in management of critically ill-patients is not routinely estimated in clinical practice owing to labour intensive, intricate and time consuming nature of existing methods. Aims: The aim was to compare blood volume estimations using trivalent chromium [51 Cr(III)] and standard Evans blue dye (EBD) method in New Zealand white rabbit models and establish correction-factor (CF). Materials and Methods: Blood volume estimation in 33 rabbits was carried out using EBD method and concentration determined using spectrophotometric assay followed by blood volume estimation using direct injection of 51Cr(III). Twenty out of 33 rabbits were used to find CF by dividing blood volume estimation using EBD with blood volume estimation using 51Cr(III). CF is validated in 13 rabbits by multiplying it with blood volume estimation values obtained using 51Cr(III). Results: The mean circulating blood volume of 33 rabbits using EBD was 142.02 ± 22.77 ml or 65.76 ± 9.31 ml/kg and using 51Cr(III) was estimated to be 195.66 ± 47.30 ml or 89.81 ± 17.88 ml/kg. The CF was found to be 0.77. The mean blood volume of 13 rabbits measured using EBD was 139.54 ± 27.19 ml or 66.33 ± 8.26 ml/kg and using 51Cr(III) with CF was 152.73 ± 46.25 ml or 71.87 ± 13.81 ml/kg (P = 0.11). Conclusions: The estimation of blood volume using 51Cr(III) was comparable to standard EBD method using CF. With further research in this direction, we envisage human blood volume estimation using 51Cr(III) to find its application in acute clinical settings.

Publisher

Georg Thieme Verlag KG

Subject

Surgery

Reference22 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3