An in vivo study to assess and compare the angular, linear, and depth deviation as well as the difference in bone density of implants placed using computer-aided design/computer-aided manufacturing fabricated three-dimensional guides versus the implants placed using bone pen kit in maxillary and mandibular ridges

Author:

Aggarwal Shipra1,Aggarwal Sumit1,Goswami Roma1,Mowar Apoorva2,Tomar Nitin3,Saxena Deepesh1

Affiliation:

1. Department of Prosthodontics and Crown and Bridge, Subharti Dental College, Swami Vivekanand Subharti University, Meerut, Uttar Pradesh, India

2. Department of Oral and Maxillofacial Surgery, Subharti Dental College, Swami Vivekanand Subharti University, Meerut, Uttar Pradesh, India

3. Department of Periodontology and Implantology, Subharti Dental College, Swami Vivekanand Subharti University, Meerut, Uttar Pradesh, India

Abstract

Aim: The aim is to assess and compare angular, linear, and depth deviation and difference in bone density of dental implants placed using computer aided design/computer aided manufacturing (CAD/CAM) fabricated surgical guides versus implants placed using Bone Pen Kit. Till now, no original research exists in the search engines such as Pubmed, Google Scholar, Science Direct, and Research Gate on this kit. Settings and Design: In vivo- Randomised control trial. Materials and Methods: Twenty clinical cases were selected and split into two distinct groups. Group 1 involved the placement of 10 implants using CAD/CAM fabricated three dimensional guides and Group 2 involved the placement of 10 implants using Bone Pen Kit. Four deviation parameters were evaluated, which included: (a) Angular deviation, (b) Linear deviation at implant platform, (c) Linear deviation at implant apex, and (d) Depth deviation and difference in bone density before and after implant placement was also evaluated. Statistical Analysis Used: SPSS software version 23 was utilized for the analysis of the data. The comparison was made using the Whitney test, and Wilcoxon signed rank test. Results: When comparing angular deviation, the results indicated a statistically significant difference with a P < 0.05. The values observed for angular and linear deviation in Group 2 were significantly greater than those in Group 1. No statistically significant difference in depth and linear deviation was found at the implant platform among the two groups. Bone density before and after implant placement was significantly higher in Group 1. Conclusions: (1) Angular and linear deviation at the apex in Group 2 exhibited higher values in comparison to Group 1, (2) No difference in depth and linear deviation at the implant platform was found among the two groups, and (3) There was no difference in change in bone density among two groups.

Publisher

Medknow

Subject

General Dentistry,Oral Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3