Assessment of occlusion changes during laboratory phase of relining: An in vitro study

Author:

Verma Ayush1,Prasad D. Krishna1,Hegde Chethan1

Affiliation:

1. Department of Prosthodontics and Crown and Bridge, A B Shetty Memorial Institute of Dental Sciences, NITTE (Deemed to be University), Mangalore, Karnataka, India

Abstract

Aim: Assessment of occlusion changes during laboratory phase of relining is essential to evaluate the occlusal discrepancies that could get incorporated in the denture with the use of different relining materials. Since the long term stability and functional success of the denture is heavily influenced by occlusion, an In-vitro study to assess these changes after relining is warranted. The aim of the study is to evaluate the changes in occlusion during laboratory phase of relining procedure. Settings and Design: This is an in vitro study with a total of 30 specimen. Materials and Methodology: A total of 30 maxillary standardized dentures were fabricated after mounting on a semi adjustable articulator. These samples will be divided into three groups based on the relining material used (Autopolymerizing resin, Heat-cure resin, Tissue conditioner). The vertical dimension, Centric contact points and eccentric contact points were measured before and after relining. Statistical Analysis Used: The variables were tested to see if they had a normal distribution using the Shapiro-Wilk test. Parametric distribution was seen for ECP leading to further comparison using one way analysis of variance (ANOVA). Non-parametric distribution was found while testing the VD, CCP leading to adoption of Kruskal-wallis test for comparison of groups. Dunn Bonferroni test was done for VD since results were significant. Results: The results of this in-vitro study showed statistically significant difference with respect to change in vertical dimension in all groups pre and post relining (P = 0.005). The centric contact points showed lesser variation in position when comparing the pre to the post relining phase with the use of autopolymerising resins, whereas heat cure resins and tissue conditioners showed statistically significant difference in the centric point contacts post relining. No statistically significant changes were seen in eccentric occlusion post relining in all groups. Tissue conditioners showed minimum mean changes in eccentric contacts. Conclusion: Within the limitations of this study, the use of autopolymerising resins depicted the most stable results with respect to occlusion, for relining of dentures.

Publisher

Medknow

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3