A novel technique to detect cover screw location at stage two uncovery surgery over conventional technique - A randomized controlled trial

Author:

Deshmukh Madhura1,Venugopalan Suresh1,Maiti Subhabrata1,Wadhwani Varun1

Affiliation:

1. Department of Prosthodontics and Implantology, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, Tamil Nadu, India

Abstract

Aim: The conventional technique of implant uncovery using a blade and scalpel is associated with various drawbacks, including profuse bleeding, soft-tissue trauma, delayed healing, and patient noncompliance. Therefore, there is a need to explore the alternative approaches that offer improved accuracy and time efficiency during the cover screw location at the second stage of recovery. This study aims to assess the accuracy and time efficiency of a novel technique that utilizes an apex locator in comparison to conventional locating techniques for implant uncovery. Settings and Design: The study employed a simple randomized controlled trial with a sample size of 161. Materials and Methods: The study employed apex locator (Woodpecker Woodpex III Gold 5th generation) in conjunction with a K-file (Mani k-file #10, 21 mm) for detecting the implant location. The accuracy of the novel technique was determined based on the values measured on the apex locator, with positive values indicating soft-tissue response and negative values indicating the cover screw (metal). The accuracy was cross-verified using radiovisiography (RVG). The clinician-based scoring was also done, considering RVG evaluation, amount of incision given, and ease of the procedure. The time required to locate the cover screw was recorded using a timer for both the novel technique and the conventional method. Statistical Analysis Used: All the recorded values were statistically analyzed using the independent t-test (P < 0.005) with the SPSS software (version 23). Results: The results revealed a significant difference in terms of incision given, ease of treatment, and time taken for the procedure (P < 0.05), while the accuracy of the novel technique was not disturbed (P > 0.05). Conclusion: Based on the findings of this in vivo study, the use of an apex locator as an alternative to conventional methods for detecting cover screw location at the second stage of recovery is recommended. The novel technique demonstrated faster uncovering of implants without posing any risks to the surrounding tissues or implants.

Publisher

Medknow

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3