Effect of different concentrations of titanium and silver nanoparticles on maxillofacial silicone MDX4-4210 on cell viability, tear bond strength, and shore strength: An in vitro study

Author:

Kumari Shweta1,John Peter1,Chidambaranathan Ahila Singaravel1,Muthukumar Balasubramanium1

Affiliation:

1. Department of Prosthodontics, SRM Dental College, Chennai, Tamil Nadu, India

Abstract

Aim: The aim was to evaluate and compare the cell viability, tear bond strength, and shore hardness of MDX4-4210 silicone reinforced with titanium dioxide and silver nanoparticles in 1%, 2%, and 3%. Settings and Design: The study design involves in vitro comparative study. Materials and Methods: MDX4-4210 silicone incorporated with 1%, 2%, and 3% by weight of silver and titanium dioxide nanoparticles. A total of 112 specimens were prepared and grouped into 7, with 16 specimens in each group. Group 1 - control, Groups 2, 3, and 4 were 1%, 2%, and 3% silver, respectively. Groups 5, 6, and 7 were 1%, 2%, and 3% titanium dioxide nanoparticles, respectively. Cell viability was tested by MTT ASSAY on MG63 cell lines, tear bond strength was tested by peeling force in universal testing machine, and Shore A hardness was tested in durometer. Statistical Analysis Used: The cell viability values were statistically analysed using one-way analysis of variance, and Tukey honestly significant difference test, tear bond strength and shore hardness values were analysed using Mann–Whitney test. Results: Based on the MTT ASSAY test, 1% silver nanoparticles incorporated MDX4-4210 silicone showed maximum cell viability of 42.10%, whereas minimum cell viability was 18.06% for 3% of titanium dioxide-reinforced silicone. The mean value of tear bond strength of 1% silver and 1% titanium dioxide nanoparticles reinforced room temperature vulcanized maxillofacial silicone were 62.81 ± 3.637 N/m and 59.69 ± 5.313 N/m and the mean value of shore hardness of room temperature vulcanized of 1% silver and 1% titanium dioxide nanoparticles reinforced room temperature vulcanized maxillofacial silicone were 38.06 ± 1.237 and 36.75 ± 1.291. Conclusion: Cell viability of 1% silver nanoparticles reinforced MDX4-4210 silicone was higher in comparison to the other groups, and tear bond strength and shore hardness were significantly higher in 1% silver nanoparticles reinforced silicone compared to 1% titanium nanoparticles reinforced MDX4-4210 silicone.

Publisher

Medknow

Subject

General Dentistry,Oral Surgery

Reference16 articles.

1. Materials of facial prosthesis:History and advance;Alqutaibi;Int J Contemp Dent Med Rev,2015

2. Fahmy AE Effect of surface treated silicon dioxide nanoparticles on some mechanical properties of maxillofacial silicone elastomer;Zayed;Int J Biomater,2014

3. Materials in maxillofacial prosthetics;Chalaian;J Biomed Mater Res,1974

4. In vitro comparison study of MDX-4-4210 and polydimethyl siloxane silicone materials;Abdelnnabi;J Prosthet Dent,1984

5. Assessment of in vitro cytotoxicity of four RTV-silicone elastomers used for maxillo-facial prostheses;Hensten-Pettersen;Acta Odontol Scand,1980

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3