Accuracy of dental implant placement using chairside computer-aided surgery/computer-aided manufacturing-milled guides compared to three-dimensional printed guides

Author:

Moufti Mohamed Adel1,Gangotra Karen2,Zuendorf Gerhard3,Seoudi Noha456,Almasri Maher4

Affiliation:

1. Department of Preventive and Restorative Dentistry, College of Dental Medicine, University of Sharjah, United Arab Emirates

2. Clinical Dental Implantology, BPP University, United Kingdom

3. Digital Manufacturing, SICAT GmbH and Co. KG, Bonn, Germany

4. Research, Clinical and Diagnostic Oral Sciences Units, College of Medicine and Dentistry, Ulster University, Birmingham United Kingdom

5. Centre of Oral Immunobiology and Regenerative Medicine, Queen Mary University of London, London, United Kingdom

6. Oral Medicine Department, Cairo University, Giza, Egypt

Abstract

Background: In-office devices are increasingly used in dental practices to mill “chairside” restorations for increased turnover. New functions permit milling implant surgical guides, thus cutting the time and cost of treatment. This study compares the accuracy of chairside-milled surgical guides (CMG) with that of high-accuracy laboratory-based three-dimensional (3D)-printed guides (PGs). Methods: In this in vitro study, 10 bone-level cylindrical implants (4 mm × 13 mm) were placed using both guide types (five for each) in 10 similar prefabricated plastic models with the aid of a specially designed machine. The positions of the placed implant were compared to the planned positions by superimposing postsurgical cone-beam computed tomography scans over the preoperative scans and by measuring the horizontal, vertical, and angular deviations within each study group. Results: The horizontal deviation at the implant neck was 0.37 mm ± 0.16 for CMG and 0.84 mm ± 0.35 for PG (P < 0.05). The horizontal deviation at the apex was greater; 0.76 mm ± 0.49 for CMG and 1.70 mm ± 0.46 for PG (P < 0.05). The vertical deviations in both groups were smaller than the horizontal values and almost identical at the neck and apex within each group (0.26 mm ± 0.13) and (0.37 mm ± 0.25) for CMG and PG, respectively (P > 0.05). The angular deviation of the implant's long axis for PG (4.10° ± 1.96°) was twice as large as CMG (2.0° ± 1.37°), but the difference was not statistically significant (P = 0.08). Conclusion: Chairside milled guides demonstrated higher accuracy and predictability compared to laboratory-based 3D-PGs.

Publisher

Medknow

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3