Comparative evaluation of fracture resistance and push-out bond strength of glass fiber post with composite core and single-unit post and core system luted with two different resin cements: An in vitro study

Author:

Garg Ishika1,Kumar Pragya1,Taneja Sonali2

Affiliation:

1. ITS-Centre for Dental Studies and Research, Ghaziabad, Uttar Pradesh, India

2. Department of Conservative Dentistry and Endodontics, ITS-Centre for Dental Studies and Research, Ghaziabad, Uttar Pradesh, India

Abstract

ABSTRACT Aim: The aim of the study was to compare the fracture resistance and push-out bond strength of glass fiber post (GFP) with composite core and single unit post and core system luted with two different resin cements. Methods: Sixty-four mandibular premolars were chosen as the sample for the study. Sample preparation was done, and specimens were randomly divided into two groups (n = 32) each according to the type of post used: Group I – RelyX GFP, Group II – Edelweiss post and core. They were further subdivided in two subgroups based on luting cements: subgroup A: RelyX U200 Adhesive Resin cement and subgroup B: SoloCem resin cement. Fracture resistance was measured in half of the prepared specimens by subjecting a load of 1 mm/min. The load was subjected along the long axis of the tooth at an angle of 45° until failure occurred using the universal testing machine. Half of the samples were divided into three horizontal thirds, i.e., coronal, middle, and apical, and push-out bond strength was evaluated at a rate of 0.5 mm/min. The scores were subjected to statistical analysis using independent t-test and SPSS Version 22.0. Results: Group I showed nonsignificantly better fracture resistance than Group II irrespective of type of luting agent used. Subgroup B showed nonsignificantly higher fracture resistance than subgroup A irrespective of the post used. Subgroup B was nonsignificant better push-out bond strength than Subgroup A (P < 0.05). Push-out bond strength of Group II was significantly better than Group I irrespective of the luting agent. Conclusion: Fiber post showed nonsignificantly better fracture resistance than Edelweiss post and core system. SoloCem showed nonsignificantly better fracture resistance and push-out bond strength with Edelweiss than RelyX U200.

Publisher

Medknow

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3