Rates and Predictors of Structural Valve Degeneration and Failure of Trifecta Bioprosthetic Valve Over a 5-year Follow-up Period: A Single-center Experience

Author:

Hashem Anas Mohamad1,Elkhapery Ahmed1,Mohamed Amr2,Buttar Rupinder1,Khalouf Amani1,Mohamed Mohamed Salah1,Abbas Faiz3,Rehman Saif ur1,Eisa Mahmoud1,Baibhav Bipul3,Rai Devesh3,Depta Jeremiah P.3

Affiliation:

1. Department of Internal Medicine, Rochester General Hospital, Rochester, New York

2. Department of Cardiovascular, Allegheny General Hospital, Pittsburgh, Pennsylvania

3. Department of Cardiovascular, Sands-Constellation Heart Institute, Rochester General Hospital, Rochester, New York, United States of America

Abstract

Abstract Introduction: The Trifecta bioprosthetic valve has been commonly used for surgical aortic valve replacement (SAVR). Multiple studies have been done to define the rate of structural valve degeneration (SVD) and failure (SVF), but the outcomes are still debatable. Therefore, we aim to conduct this single-center study to estimate the rate and predictors of SVD/SVF. Methodology: This retrospective observational cohort single-center study was conducted between 2014 and 2019 among Trifecta SAVR patients. Data were patient’s characteristics collected from electronic medical records at baseline and follow-up (3–5 years). Statistical analysis was performed with a significance level of P ≤ 0.05. Results: A total of 271 eligible patients were identified. Most of our sample were males (57.9%), with a mean age of 71.1 ± 10.6 years. The mean baseline preoperative ejection fraction (EF) was 53.0%, with no change (P = 0.88) in the immediate postoperative EF (53.6%). A most recent follow-up EF revealed a significant increase of EF (55.2%), P = 0.01. Furthermore, there was a significant increase from peak velocity to PVMRE (mean difference [MD] ± standard error of mean (SEM) [0.15 ± 0.04], P < 0.01), an increase in pressure gradient (PGIPE) to PGMRE (MD ± SEM [1.70 ± 0.49], P < 0.01), and a decrease in Doppler velocity index (DVIIPE) to DVIMRE (MD ± SEM [−0.037 ± 0.01], P = 0.01). Regarding the SVF rate, 13 (4.8%) patients had failed valves requiring replacement throughout the study period. Conclusions: Over a 5-year follow-up period, 4.8% had SVF with an SVD of 23.2%, with the majority of SVD not being clinically significant except in six patients. These results corroborate with a previously published study suggesting a bad clinical outcome of Trifecta valve placement.

Publisher

Medknow

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3