Phytic Acid: A Novel Dentine Conditioning Agent for Glass Ionomer Cement Restorations: An In Vitro Scanning Electron Microscopic Study

Author:

Souparnika D. P.1,Babu Binila S.2,Shetty Nithin3,Imteyaz Fareeha4,Parthiban Gayathri4,Kumar G. Vinay5

Affiliation:

1. Department of Conservative Dentistry and Endodontics, Bangalore Institute of Dental Sciences and Hospital, Bengaluru, Karnataka, India

2. Department of Conservative Dentistry and Endodontics, Al Azhar Dental College, Thodupuzha, Kerala, India

3. Faculty of Dental Science, Ramaiah University of Applied Science, Bengaluru, Karnataka, India

4. Department of Conservative Dentistry and Endodontics, KLE Society’s Institute of Dental Science, Bengaluru, Karnataka, India

5. Department of Conservative Dentistry and Endodontics, R. V. S. Dental Collage and Hospital, Coimbatore, Tamil Nadu, India

Abstract

ABSTRACT Background: Various dentin conditioners have been recommended to enhance the bond strength of glass ionomer cement (GIC) to dentin. The purpose of the in vitro study was to determine the efficacy of three dentin conditioners on the microshear bond strength of GIC and the failure patterns of the restoration, as well as the efficacy of removing the smear layer using a scanning electron microscope (SEM). Materials and Methods: Eighty healthy mandibular premolars were cleaned, isolated, and divided into four groups (n = 20). Flat coronal dentinal surfaces were accomplished by removing the occlusal surface of the crowns. Each group received the following treatment: group 1 with 10% polyacrylic acid; group 2 with 10% ethylenediaminetetraacetic acid (EDTA); group 3 with 1% phytic acid; and group 4 with no conditioning (control). High-strength Fuji IX GIC was applied to the dentin, and samples were thermocycled and de-bonded with a crosshead speed of 0.5 mm/min employing a shear force. A stereomicroscope and a SEM were used to examine the dentin surface at magnifications of 2000× and 5000×. One-way analysis of variance (ANOVA), Tukey’s post hoc test, and Chi-squared test were used to assess data on microshear bond strength, smear layer removal, and failure modes. Results: The bond strength of group 4 was statistically highly significant (P ≤ 0.001) compared to the other groups. However, the differences between groups 2 and 3 were insignificant. Mixed pattern of failure was the least in group 3 (IP6). In group 3, the SEM photomicrograph revealed open dentinal tubules with complete removal of the smear layer. Conclusion: The results of the present study affirm that phytic acid enhances the bond strength of GIC restorations and removal of smear layer to a level comparable to EDTA as a dentin conditioner.

Publisher

Medknow

Subject

General Pharmacology, Toxicology and Pharmaceutics,General Biochemistry, Genetics and Molecular Biology,Bioengineering,General Pharmacology, Toxicology and Pharmaceutics,General Biochemistry, Genetics and Molecular Biology,Bioengineering

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3