Estimation of the Mechanical Properties of PRF in the Implant Surgery: An Original Research

Author:

Karpathak Shilpi1,Mansuri Samir2,Dev Shruti Vishal3,Pilli Jyostnadevi4,Alwithanani N.5,Kondreddy Kameswari6

Affiliation:

1. Department of Prosthodontics, Rungta College of Dental Sciences and Research, Bhilai, Chhattisgarh, India

2. Consultant Oral and Maxillofacial Surgeon, Ahmedabad, Gujrat, India

3. Department of Prosthodontics, Kalinga Institute of Dental Sciences, KIIT University, Patia, Bhubaneswar, Odisha, India

4. Private Practitioner, SMS Dental Hospital, Visakhapatnam, Andhra Pradesh, India

5. Department of Oral and Maxillofacial Surgery and Diagnostic Science, Taif University, Taif, Saudi Arabia

6. Department of Periodontics, Faculty of Dentistry, AIMST University, Semeling, Bedong, Kedah, Malaysia

Abstract

ABSTRACT Introduction: In many oral procedures that involve the implants, hair implantations, “Platelet-Rich Fibrin Membrane (PRF)” is commonly applied. The advantages are many. In this study, the mechanical resistance of PRF under resistance pull on a longitudinal axis was assessed and compared. Material and Methods: For the current in vitro study, 60 volunteers donated each 10 ml of their blood and hence a total volume of 600 ml of blood was procured that was analyzed for the current study. The total volume was grouped to three groups where they receive three resistance centrifugation forces of “F-200,600,800 m/s².” In each group, 20 samples were tested for each level of the G-resistance. Each group was further divided as two subgroups of different times of wait, where they were centrifuged at baseline time and after a stand of 30 minutes. On universal testing equipment, the PRF membranes were mechanically tensioned in order to determine each membrane’s resistance force. These values were compared for any statistical variance using appropriate statistical tools keeping P < 0.05. Results: Any applied force had no statistically significant effect on the centrifugation duration for membrane resistance. When the resistance was applied for the PRP samples immediately after they were procured, no significant variation was seen at all the grades of the centrifugation forces; consequently, the T30 group showed a statistically significant variance for the centrifugation forces applied (P = 0.04), with the highest value when the greatest force was applied. According to the results, the centrifugation waiting period could be determined based on the application requirement. Conclusion: For immediate membrane usage, the centrifugation had no effect on resistance; however, after 30 minutes, a membrane with greater resistance was produced by applying more force.

Publisher

Medknow

Subject

General Pharmacology, Toxicology and Pharmaceutics,General Biochemistry, Genetics and Molecular Biology,Bioengineering,General Pharmacology, Toxicology and Pharmaceutics,General Biochemistry, Genetics and Molecular Biology,Bioengineering

Reference23 articles.

1. Plasma rich in growth factors:Preliminary results of use in the preparation of future sites for implants;Anitua;Int J Oral Maxillofac Implants,1999

2. Soft tissue wound healing around teeth and dental implants;Sculean;J Clin Periodontol,2014

3. The first stem cell-based tissue-engineered organ replacement:Implications for regenerative medicine and society;Hollander;Regen Med,2009

4. Use of platelet-rich fibrin in regenerative dentistry:A systematic review;Miron;Clin Oral Investig,2017

5. Platelet-rich fibrin (PRF):A second-generation platelet concentrate. Part I:Technological concepts and evolution;Dohan;Oral Surg Oral Med Oral Pathol Oral Radiol Endod,2006

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3