Effectiveness of Miniscrew-Supported Molar Intrusion: A Clinical Study

Author:

Patel Sejal D.1,Ghosh Anirban2,Parashar Pranav3,Shenavi Lina4,Agarwal Satendra Kumar5,Rawat Siddharth6,Makkad Ramanpal Singh7

Affiliation:

1. Department of Orthodontics and Dentofacial Orthopaedics, Government Dental College and Hospital, Jamnagar, Gujarat, India

2. Department of Orthodontics and Dentofacial Orthopedics, Bhabha College of Dental Sciences, Bhopal, Madhya Pradesh, India

3. Department of Dentistry, N.S.C.B Medical College and Hospital, Jabalpur, Madhya Pradesh, India

4. Department of Orthodontics and Dentofacial Orthopedics, College of Dental Sciences and Hospital, Bhavnagar, Amargadh, Gujarat, India

5. Department of Orthodontics and Dentofacial Orthopaedics, KGF College of Dental Sciences and Hospital, Karnataka, India

6. Department of Oral and Maxillofacial Surgery, School of Dental Sciences, Sharda University, Greater Noida, Uttar Pradesh, India

7. Department of Oral Medicine and Radiology, New Horizon Dental College and Research Institute, Sakri, Bilaspur, Chhattisgarh, India

Abstract

ABSTRACT Mini-screws, also known as temporary anchorage devices (TADs), offer enhanced control and versatility in orthodontic treatment by providing stable anchorage points. This clinical study aims to evaluate the effectiveness of mini-screw-supported molar intrusion in orthodontic practice. For this clinical study, a cohort of 40 orthodontic patients with various malocclusions requiring molar intrusion as part of their treatment plan was recruited. The age range of the participants spanned from 14 to 35 years, representing a diverse patient population. The intervention involved the implementation of mini-screw-supported molar intrusion on one side of the maxillary arch in each patient. To achieve this, temporary mini-screws were strategically placed, and a combination of orthodontic forces and mini-screw anchorage was employed to intrude the molars. The primary outcome measure for this study was the amount of molar intrusion achieved, which was quantified in millimeters from the initial evaluation to the final visit. Additionally, the duration of treatment required to achieve the desired molar intrusion was recorded in months. The results of this clinical study demonstrated that mini-screw-supported molar intrusion was an effective and safe orthodontic technique. On average, a significant mean molar intrusion amount of 4.8 mm (standard deviation [SD] ± 0.6) was achieved with the mini-screw-supported approach. Furthermore, the treatment duration required to attain the desired molar intrusion was relatively short, with a mean of 6.2 months (SD ± 1.1). In conclusion, this clinical study provides evidence that mini-screw-supported molar intrusion is an effective and safe approach in orthodontic practice. It offers orthodontists the advantage of enhanced control and predictability in molar intrusion procedures.

Publisher

Medknow

Subject

General Pharmacology, Toxicology and Pharmaceutics,General Biochemistry, Genetics and Molecular Biology,Bioengineering,General Pharmacology, Toxicology and Pharmaceutics,General Biochemistry, Genetics and Molecular Biology,Bioengineering

Reference9 articles.

1. Deep overbite correction by intrusion;Burstone;Am J Orthod Dentofacial Orthop,1977

2. Miniscrews as orthodontic anchorage:A preliminary report;Costa;Int J Adult Orthodon Orthognath Surg,1998

3. Mini-implant stability at the initial healing period:A clinical pilot study;Nienkemper;Head Face Med,2013

4. Group distal movement of teeth using microscrew implant anchorage;Park;Angle Orthod,2005

5. Distalization of maxillary molars with a midpalatal miniscrew;Kyung;J Clin Orthod,2003