Quality assessment of platelet concentrates prepared by platelet-rich plasma, buffy-coat, and apheresis methods in a tertiary care hospital in South India: A cross-sectional study

Author:

Toora Esha1,Kulkarni Rajendra G.1,Manivannan Prabhu1,Sastry Apurba Sankar1,Basavarajegowda Abhishekh1,Sahoo Dibyajyoti1

Affiliation:

1. Department of Transfusion Medicine, Jawaharlal Institute of Postgraduate Medical Education and Research, Puducherry, India

Abstract

Abstract INTRODUCTION: In blood banking and transfusion medicine, it is of paramount importance to improve transfusion safety and provide a higher quality of product to maximize the therapeutic outcomes and minimize the risk of developing transfusion-associated complications for patients receiving a blood transfusion. MATERIALS AND METHODS: This was a cross-sectional study conducted at the department of transfusion medicine in a tertiary care hospital of South India from February 2019 to December 2020. The primary objective of the study was to assess the quality of platelet concentrates (PC) prepared by platelet-rich plasma (PRP), buffy-coat (BC), and apheresis method. A total of 760 PCs were subjected to quality assessment, among which 124 were PRP-PC, 176 were BC-PC, and 460 were single donor platelet (SDP). RESULTS: The total percentage of platelets meeting all the six quality control parameters in PRP, BC and SDP was 78.23%, 81.81%, and 89.96%, respectively. Apheresis PCs showed a significantly higher platelet concentration per µL on comparison with whole-blood-derived platelets. BC-PCs were found to be better than PRP-PC with regard to lower white blood cell (WBC) contamination (P < 0.05) and red blood cell (RBC) contamination (P < 0.01). No statistically significant difference was found with regard to platelet yield, volume, swirling, and pH. CONCLUSION: Ex vivo quality of PCs prepared by BC-PC, PRP-PC, and apheresis-PC fulfilled the desired quality control parameters. BC-PC was better than PRP-PC in terms of lesser WBC and RBC contamination and comparable in terms of volume, platelet yield, swirling, and pH. Apheresis PCs showed a higher platelet concentration per microliter on comparison with whole-blood-derived platelets; hence in a blood center where facilities for collection of apheresis product are available, SDPs should be the choice of platelet transfusion.

Publisher

Medknow

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3