Diagnostic Utility of Reticulocyte Hemoglobin Equivalent Parameter in the Evaluation of Microcytic Hypochromic Anemia – Our Experience from Northeast India

Author:

Rao H. R. Sohan1,Mirji Sadiya2

Affiliation:

1. Department of Pathology, Central Referral Hospital, Sikkim Manipal Institute of Medical Sciences, Sikkim Manipal University, Gangtok, Sikkim, India

2. Department of Pathology, Al-Ameen Medical College, Vijayapura, Karnataka, India

Abstract

Background: Reticulocytes are red blood cell precursors with an average lifespan of 1–2 days. Reticulocyte hemoglobin equivalent (Ret-He) is an early marker of iron deficiency (ID) erythropoiesis and reflects real-time information regarding the synthesis of young erythrocytes in the bone marrow. The objective of this study is to determine the diagnostic utility of Ret-He in patients having microcytic hypochromic anemia in comparison with serum ferritin and iron studies. Objectives: The objective of this study is to determine the diagnostic utility of the Ret-He parameter in patients having microcytic hypochromic anemia in comparison with the serum ferritin, iron studies and its role in routine hematological screening for nutritional deficiency anemia like ID. Design and Settings: The design involves observational study. Materials and Methods: A hospital-based observational study was carried out in a referral hospital. Hematological parameters were processed using Sysmex XN1000 (Sysmex Corporation, Kobe, Japan) analyzer and were compared with Serum iron studies using biochemistry analyzer (VITROS® 250 Chemistry System) from 201 participants who presented with microcytic hypochromic anemia. Main Outcome and Measures: Relationship of Ret-He parameter and its diagnostic utility for screening of iron-deficient states. Sample Size: The sample size was 201. Results: When serum ferritin is taken as “the gold standard” to detect ID, with Ret-He cutoff of 27.15 pg/cell, we found a statistically significant positive correlation between Ret-He and serum ferritin (P < 0.001). We found a sensitivity of 57.37% and specificity of 75.95% with area under the curve of 0.681, positive predictive value of 100%, negative predictive value of 3.8%, and accuracy of 62.19% for Ret-He in detecting ID anemia (IDA). Also found a statistically significant negative correlation between Ret-He and total iron binding capacity (P < 0.001). There was no statistical correlation between Ret-He and serum iron levels in our study. Conclusions: The present study suggests Ret-He is one of the better and more reliable hematological parameters indicating ID and, when used along with biochemical parameters like serum ferritin, can give valuable inputs in a better screening and diagnosis of IDA; hence proper treatment is possible. Limitations: The multicentric study is required to standardize Ret-He reference values, and follow-up to therapy of the subjects was not done. Additional hemoglobin variant analysis data would have been favorable to the study.

Publisher

Medknow

Reference33 articles.

1. Iron deficiency anaemia;Lopez;Lancet,2016

2. Nutritional Anemias: Tools for Effective Prevention and Control,2017

3. Application of innovative hemocytometric parameters and algorithms for improvement of microcytic anemia discrimination;Schoorl;Hematol Rep,2015

4. Reticulocyte hemoglobin equivalent (Ret-He) combined with red blood cell distribution width has a differentially diagnostic value for thalassemias;Lian;Hemoglobin,2019

5. Reticulocyte hemoglobin equivalent (RET-He) as a predictor of response to intravenous Iron in hemodialysis patients: A hospital based analytical study;Fathy;Life Science Journal,2018

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3