Tissue plasminogen activator versus heparin for locking dialysis catheters: A systematic review

Author:

Firwana Belal M1,Hasan Rim1,Ferwana Mazen2,Varon Joseph3,Stern Aaron4,Gidwani Umesh5

Affiliation:

1. Department of Medicine, University of Damascus, Damascus, Syria

2. Department of Medicine, King Saud Bin Abdulaziz University for Health Sciences, Riyadh, Saudi Arabia

3. Department of Medicine, The University of Texas Health Science at Houston, Houston, Texas, USA

4. Division of Nephrology, Elmhurst Hospital Center, New York, USA

5. Cardiovascular Institute, Mount Sinai Medical Center, New York, USA

Abstract

Abstract Background and Objectives: Hemodialysis catheters are commonly used when renal replacement therapy is initiated. These catheters have significant complications. Among "locking" solutions used in an attempt to decrease these complications is recombinant tissue plasminogen activator (rt-PA). This systematic review is to determine the efficacy of rt-PA versus heparin, the standard of care. Materials and Methods: A systematic review of randomized controlled trials studying rt-PA alone or rt-PA plus heparin versus heparin alone as locking agents for hemodialysis catheters, which included patients needed a temporary hemodialysis catheter for hemodialysis. We identified relevant trials through electronic databases and correspondence with experts. Two investigators independently reviewed potentially eligible trials and extracted data. Results: Three trials met the inclusion criteria. One trial reported an improved catheter malfunctioning in patients using rt-PA plus heparin to lock catheters (20.0%) versus heparin alone (34.8%). Another trial reported higher blood flow rate in hemodialysis catheters in patients who received rt-PA (231.6 ± 12.4 mL/min) compared with those who received heparin (206.9 mL/min). The third trial reported formation and weight of clots which were decreased by half in rt-PA group versus heparin group. Conclusions: In the few randomized trials that met our inclusion criteria, the use of rt-PA as a locking solution for hemodialysis catheters seems to be associated with fewer adverse events and catheter malfunctioning as compared with heparin. Our systematic review is limited by the few randomized trials addressing our question and the wide variety of outcome measures. Further prospective randomized trials are needed to confirm this conclusion.

Publisher

Georg Thieme Verlag KG

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3