An In-depth Analysis of the Effects of Preheating Three Different Composite Resin Systems at Two Different Temperatures on Their Microhardness

Author:

Bhopatkar Jay1,Ikhar Anuja1,Nikhade Pradnya1,Chandak Manoj1,Agrawal Paridhi1

Affiliation:

1. Department of Conservative Dentistry and Endodontics, Sharad Pawar Dental College and Hospital, DMIMSU (DU), Wardha, Maharashtra, India

Abstract

Abstract Background: Composite restorations often have inferior physical properties compared to natural enamel and dentin, leading to early failure. Preheating the traditional composite before its placement and curing seems to enhance all its physical characteristics magically. The objective of the current research was to assess the impact of preheating on the surface microhardness of commonly used composite resin materials, specifically FILTEK P60, FILTEK Z250XT, and Tetric-N-Ceram Bulk fill. Materials and Methods: The resin composite tubes were either left at the ambient room temperature (24°C ± 1°C) or preheated in a commercial preheating device to 50°C and 60°C for 40 min. By inserting uncured preheated composite resin into class II Mseio-Occluso-Distal (MOD) cavities with specifications of 2 ± 0.3 mm axial height, 2 ± 0.3 mm pulpal depth, parallel proximal walls with a 3 ± 0.3 mm buccolingual width, 1.5 ± 0.3 mm gingival width, and an occlusal isthmus width equal to one-third of the intercuspal distance from composite resin tubes, a total of 99 class II MOD cavities on premolars were established. Each specimen’s Vicker’s hardness number (VHN) was determined. The gathered information was examined utilizing a two-way ANOVA and Tukey’s post hoc test with a significance threshold of 0.05. Results: When preheated to the temperatures of 50°C and 60°C, a remarkable rise in the mean Vickers hardness numbers (VHNs) of all the resin composites compared to those maintained at the room temperature (P < 0.05) was seen. The mean VHNs at the room temperature for FILTEK P60, FILTEK Z250XT, and Tetric-N-Ceram were 47.27 ± 9.08, 59.63 ± 1.56, and 75.69 ± 0.80, respectively, with a significant variation between all of them (P < 0.05). The mean VHNs were, respectively, 108.45 ± 2.42, 103.45 ± 1.29, and 113.00 ± 4.35 at 50°C, with a significant variation between them all. At 60°C, the mean VHNs were, respectively, 121.09 ± 1.30, 128.00 ± 0.89, and 135.00 ± 2.04, with a significant variation between all of them (P < 0.05). Conclusion: The surface microhardness of all investigated composite resins was greatly increased by preheating, with Tetric N-Ceram Bulk Fill showing the greatest value at a preheating temperature of 60°C.

Publisher

Medknow

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3