Evaluation of the proximal femur using the digital photographs: Does change in proximal femur position due to anteversion affect the measurement of the size of the femoral head diameter?

Author:

Akinmokun Olasode Israel12,Edem Utibeabasi Ime2,Adeoye Olanrewaju Matthew3

Affiliation:

1. Department of Surgery, College of Medicine, University of Lagos, Idi Araba, Nigeria

2. Department of Orthopaedics and Traumatology, Lagos University Teaching Hospital, Idi Araba, Nigeria

3. Department of Surgery, Lagos University Teaching Hospital, Idi Araba, Nigeria

Abstract

Abstract Background: A plain pelvic radiograph is usually conducted with the lower limbs in internal rotation. This is to correct the anteversion of the femur. However, in the fracture neck of the femur, internal rotation of the fractured limb is avoided, because it would be painful. We examined the effect of correction of anteversion or otherwise on the diameter of the head of the femur using imaging. Objectives: This study aimed to determine if there was a significant difference between the femoral head diameter at two different positions, at the normal anatomical position (without correcting the anteversion) and at the corrected anteversion position. It also aimed to document the correlation and the statistical significance between the differences in the size of the diameter at these two different positions with the anteversion angles of the femoral bone. Materials and Methods: Two sets of digital photographs of the proximal part of 55 non-sexed, non-paired femoral bones were taken. Images obtained were at two positions: normal anatomical (with anteversion uncorrected) and anteversion corrected positions. The diameters of the head of the femur were documented at these two different positions. The anteversion angles and actual femoral head (AFH) diameters were also measured and documented. Results: The femoral head diameters at anatomical positions were persistently larger than those measured after the anteversion was corrected, except in three femoral bones (5%) where no differences were observed. The difference in the two measurements was statistically significant to the anteversion angle of the femoral bone. (P = 0.0005). The means of the two sets of measurements were statistically different from each other. Pairwise correlation showed that both were strongly associated with the AFH diameter but the measurements from images with corrected anteversion had a higher value (0.8166) than the measurements from normal anatomical position (0.7526). Conclusion: The correction of femoral anteversion produced femoral head size measurements that were closer to AFH diameters compared to those without the correction of the femoral anteversion. Femoral anteversion should always be corrected as per protocol.

Publisher

Medknow

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3