Arise Tube- A Novel Double-Lumen Suction Tube for Oesophageal Atresia

Author:

Abdur-Rahman Lukman Olajide1,Kalu Ukoha A.2,Sayomi Olayinka T.,Nasir Abdulrasheed A.1,Taiwo Jones O2

Affiliation:

1. Department of Surgery, Division of Paediatric Surgery, University of Ilorin Teaching Hospital, Ilorin, Kwara State, Lokoja, Nigeria

2. Department of Surgery, Federal Medical Centre, Paediatric Surgery Unit, Lokoja, Nigeria

Abstract

Abstract Background: Airway compromise is a major criterion that determines the outcome of care in oesophageal atresia (OA). The maintenance of dry throat through suction of the airway and throat is a vital step to the survival of neonates with OA. This prevents aspiration of saliva and mucus plugging of the airway which can compromise pulmonary function. Pre-operative aspiration pneumonitis increases the morbidity and possible mortality of neonatal OA. The Replogle® tube is usually not readily available and costly for caregivers in most centres in the low-income countries. Objective: To introduce a local adaptation of suction tubing for clearance of the airway in OA. Method and Case Series: The Abdur-Rahman Ilorin Suction oEsophageal (ARISE) suction tube is constructed with a size 6 Fr feeding tube which was tunnelled from a side opening into the lumen of a 10 Fr feeding tube. The distance of the pouch from the incisor is first measured and multiple fenestrations (1 cm apart) are made on the wall of the outer tubes sparing about 2 cm from the measured length near the incisor. Three side fenestrations are made 1.5 cm apart from the tip on the side of the inner tube. The ARISE tube is placed in the upper OA pouch to suck saliva and prevent aspiration in the neonate. The tip of tube is positioned about 0.5 cm above the blind end of the oesophageal pouch. The inner (small lumen) tube is connected to a low-pressure suction machine at 0.2KPa (−15 to −35 cm H2O) for continuous drainage of saliva and the outer (big lumen) tube functions as air vent and irrigation channel. This protects the mucosal from being sucked into the inner tube lumen. Irrigation of tube is done with 2–3 ml of 0.9% saline every 4 h and as necessary. Result: This ARISE suction tube allowed adequate and continuous suction of the pouch and throat with the baby being calm, and caregivers also stress free. The patient maintained good arterial oxygen saturation and there was no aspiration into the airway. Conclusion: The ARISE double-lumen suction tube can easily be constructed in many resource-poor health institutions where OA is managed. This will improve the pre-operative management of neonatal OA in such environment making the baby’s condition optimal for surgical intervention.

Publisher

Medknow

Subject

Pediatrics, Perinatology and Child Health,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3