Does sildenafil citrate affect the pharmacokinetics of metformin in rats? Screening of mechanism through analytical and molecular docking approach

Author:

Dewani Anil P.1,Rab Safia O.2,Tripathi Pankaj3,Shrivastava Saurabh4,Tripathi Rina3,Tripathi Alok S.5,Mohale Deepak S.6,Sheikh Naheed Waseem A.7,Nakhat Kamlesh V.6,Vekariya Hitesh J.8,Chandewar Anil V.1

Affiliation:

1. Department of Quality Assurance, P. Wadhwani College of Pharmacy, Yavatmal, India

2. Department of Clinical Laboratory, Science College of Applied Medical Sciences, King Khalid University, Abha, Saudi Arabia

3. Department of Pharmacology, Nootan Pharmacy College, Sankalchand Patel University, Visnagar, Gujarat, India

4. Division of Pharmaceutical Technology, School of Pharmacy, KPJ Healthcare University College, Nilai, Malaysia

5. Department of Pharmacology, ERA University, Lucknow, Uttar Pradesh, India

6. Department of Pharmacology, P. Wadhwani College of Pharmacy, Yavatmal, India

7. Department of Pharmacology, Hi-Tech College of Pharmacy, Chandrapur, Maharashtra, India

8. Department of Pharmachemistry, RK University, Rajkot, Gujarat, India

Abstract

Abstract: OBJECTIVE: In the present study, the effect of sildenafil on the pharmacokinetics of metformin was studied in experimental rats, and we also postulated the molecular mechanism by performing molecular docking studies. MATERIALS AND METHODS: Analysis of metformin and sildenafil (SIL) from rat plasma was done by high performance liquid chromatography. Optimum chromatographic separation and quantification of MET, SIL and Cetirizine was achieved on Phenomenex EVO C18 column with triethyl amine (0.3%): Methanol: Acetonitrile (70:05:25 v/v) as mobile phase maintaining flow rate of 1 ml/min, the detector was tuned at 224 nm. The extraction of MET and sildenafil from rat plasma was achieved by solid-phase extraction using Strata-X cartridges. The method was validated as per the ICH guidelines. For docking studies, the crystal structure of organic cation transporter 1 (OCT1) protein and multidrug and toxin extrusion (MATE) protein (5XJJ) were downloaded from the PubChem database. The docking study was performed by PyRx virtual screening software, and the results were analyzed by BIOVIA Discovery Studio. RESULTS: The validation of HPLC method was done, intraday and interday precision study of HPLC method demonstrated %RSD values less than 5%, the extraction recovery for MET and SIL were near to 80 % for low, medium and high QC samples. The plasma stability of MET and SIL showed % RSD values <10% for low, medium, and high QC samples. A sensitivity study for MET and SIL in rat plasma suggested a lower limit of quantification values of 8 and 10 ng/mL, respectively. The pharmacokinetic parameters were recorded, Cmax of experimental and control rats was 611.2 and 913.2 ng/mL; t1/2 1.66 and 1.98, AUC (0-t) 1637.5 and 2727.24, AUC (0-∞) 1832.38 and 2995.24 for MET. The results suggested that the Cmax of MET in experimental rats (MET + SIL) was 33.07% lower than the control (MET only) and also the t1/2 was 0.32 h shorter. Docking analysis suggested a higher binding affinity of sildenafil with MATE protein (5XJJ) compared to OCT1, suggesting possible involvement of MATE family proteins for pharmacokinetic alterations of MET. CONCLUSIONS: The HPLC and solid-phase extraction method were developed and applied successfully for the pharmacokinetics of MET and SIL. Intake of SIL altered the pharmacokinetics of MET in rats. Molecular docking studies suggested the involvement of MATE family proteins for alterations of MET pharmacokinetics.

Publisher

Medknow

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3