A new device, LMA Gastro™, on the horizon for endoscopy procedures: A narrative review

Author:

Gupta Anju1,Saranlal A M1,Gupta Nishkarsh2

Affiliation:

1. Anaesthesiology, Pain Medicine and Critical Care, All India Institute of Medical Sciences, New Delhi, India

2. Department of Onco-Anesthesiology and Palliative Medicine, DRBRAIRCH, AIIMS, New Delhi, India

Abstract

Abstract Interventional endoscopy procedures are challenging for anaesthesiologists due to the various patient, procedural, logistic, and position-related issues. Complex endoscopic procedures like biliary interventions and endoscopic myotomy necessitate longer procedural duration. The mode of anaesthesia is usually deep sedation without any definitive airway device and is frequently associated with hypoxemia events which can be catastrophic. An endotracheal tube, though the gold standard for securing the airway, would prolong the anaesthesia time and delay the recovery. The laryngeal mask airway Gastro™ is a novel supraglottic airway device specifically meant for these procedures as it provides access to the gastrointestinal tract simultaneously with a patent airway. Though its purported advantages are undoubted, its clinical usage has various pitfalls that can hinder its wider acceptance and practical utility, especially when newly introduced. The literature is limited on the feasibility of this device in both the ease of endoscopy and the prevention of hypoxemia. In this review, we have discussed the device’s properties, its varied use cases, the supporting evidence for the same, the caveats, and the future perspectives.

Publisher

Medknow

Reference15 articles.

1. Burden of gastrointestinal disease in the United States:2012 update;Peery;Gastroenterology,2012

2. Safety of sedation for gastrointestinal endoscopy in a group of university-affiliated hospitals:A prospective cohort study;Leslie;Br J Anaesth,2017

3. Use of the LMA®Gastro™ Airway, a novel dual-channel laryngeal mask airway, for endoscopic retrograde cholangiopancreatography:A report of two cases;Skinner;Anaesth Intensive Care,2018

4. Efficacy of a new dual channel laryngeal mask airway, the LMA®Gastro™ Airway, for upper gastrointestinal endoscopy:A prospective observational study;Terblanche;Br J Anaesth,2018

5. LMA Gastro Airway®Cuff Pilot for endoscopic retrograde cholangiopancreatography:A preliminary experience;Aiello;Minerva Anestesiol,2019

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3