Comparison of intraoperative blood pressure values measured by noninvasive versus invasive methods during normotension, hypertension, and hypotension

Author:

Irimpan Joel1,Kesavan Rajesh1,Rajan Sunil1,Kumar Lakshmi1

Affiliation:

1. Department of Anaesthesiology, Amrita Institute of Medical Sciences, Amrita Vishwa Vidyapeetham, Kochi, Kerala, India

Abstract

Abstract Background and Aims: Monitoring of intraoperative blood pressure (BP) is essential. We aimed to compare BP values simultaneously recorded by invasive and noninvasive methods under general anesthesia (GA) during normotension, hypertension, and hypotension. Mean arterial pressure (MAP) values calculated by the automated technique were also compared to the values obtained using predefined formula. Material and Methods: An observational, prospective study was conducted in 250 adult patients undergoing elective surgeries under GA. Before induction, noninvasive blood pressure (NIBP) was measured in the arm in a supine position using an automated oscillometer. Radial artery in the opposite arm was cannulated. NIBP and arterial BP (ABP) were recorded simultaneously during normotension, hypotension, and hypertension. Results: During normotension and hypertension, systolic BP (SBP) measured by NIBP and ABP were comparable. Diastolic BP (DBP) and MAP during normotension were significantly higher with NIBP (73.65 ± 7.73 vs. 65.69 ± 8.39 and 87.79 ± 8.43 vs. 84.24 ± 8.82, respectively). During hypertension, DBP and MAP were significantly higher with NIBP (90.44 ± 11.61 vs. 78.59 ± 11.09 and 111.67 ± 10.43 vs. 105.63 ± 11.06, respectively). During hypotension, SBP was significantly higher in ABP (91.14 ± 6.90 vs. 86.24 ± 6.06), and DBP and MAP were comparable. Comparison of MAP measured by ABP and NIBP techniques with the MAP calculated using predefined formula in normotension showed significantly higher values with the automated technique. Conclusions: During normotension and hypertension, DBP and MAP showed significantly higher values with the NIBP technique compared to ABP, with comparable SBP values. During hypotension, SBP showed significantly higher values with the ABP technique, with comparable DBP and MAP. MAP obtained using predefined formula and automated method in normotension was significantly higher with the automated technique.

Publisher

Medknow

Subject

Anesthesiology and Pain Medicine,Pharmacology (medical),General Pharmacology, Toxicology and Pharmaceutics

Reference18 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3