Surgical Treatment of Midshaft Clavicle Fractures with Intramedullary Titanium Elastic Nailing System

Author:

Raju G. Bharath1,Ravish V. N.1,Gowda B. M. Bharath1

Affiliation:

1. Department of Orthopaedics, Kempegowda Institute of Medical Sciences and Research Centre, Bengaluru, Karnataka, India

Abstract

Abstract Introduction: Fractures of the clavicle are common injuries with an incidence of 5%–10% of all fractures. The most common site of fracture in clavicle is the middle third and accounts for approximately 70%–80% of all clavicle fractures. Clavicle fractures are usually associated with some degree of displacement. Displaced midshaft clavicle fractures can cause significant persistent disability, even if they heal uneventfully when treated conservatively. Surgery is required in case of significant fracture displacement and associated neurovascular injuries. Fractures that require internal fixation are usually treated by plate osteosynthesis as the standard procedure. Intramedullary fixation with titanium elastic nailing system (TENS) is an increasingly popular technique for the internal fixation of displaced mid-clavicular fractures. It is a better fixation device for simple displaced midshaft clavicle fractures. Methodology: A prospective study was conducted with a sample size of 20 patients for 18 months. After obtaining approval and clearance from the institutional ethics committee, the patients fulfilling the inclusion criteria were enrolled for the study after obtaining informed consent. A thorough clinical examination of the patient was done. The diagnosis was made based on X-ray findings. All patients underwent routine preoperative investigations, and their fitness for surgery was taken. The surgery was performed under general or regional anesthesia. Constant–Murley score was used to evaluate the outcome of the study. The cases were followed for a minimum period of 6 months following surgery at the regular intervals of 6, 12, and 24 weeks. Results: The functional outcome in 17 patients was excellent with the union of the fracture site. In one case, there was fixation failure and it had to be converted into plate fixation and was excluded from the study. In four patients, there was hardware prominence at the entry site. Conclusion: TENS is a good internal fixation option for simple displaced midshaft clavicle fractures to reduce the duration of the surgery, decrease the surgical site morbidity, and early mobilization.

Publisher

Medknow

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3