Comparison of dosimetric parameters and three-dimensional dosimetric verification of three intensity-modulated radiotherapy plans for thymoma based on the dose-volume histogram and ArcCHECK-3DVH system

Author:

Zhou Peng,Luo Jia,Xiao He,Geng Mingying,He Xuan

Abstract

Objective: To compare the dosimetric parameters of step-shoot intensity-modulated radiotherapy (sIMRT), dynamic intensity-modulated radiotherapy (dIMRT), and volume-modulated arc therapy (VMAT) in thymoma and to study the feasibility of the ArcCHECK-3DVH system in three intensity-modulated radiotherapy plans to choose a more appropriate intensity-modulated radiotherapy for thymoma. Materials and Methods: Seventeen patients with thymoma were enrolled in this study. Treatment plans of sIMRT, dIMRT, and VMAT for each patient were based on the Monaco treatment planning system (TPS). Dosimetric verification was performed via the ArcCHECK-3DVH system. We compared and analyzed the 3D γ pass rates of the TPS dose calculation and ArcCHECK-3DVH system dose reconstruction with the three gamma criteria (3 mm/3%, 2 mm/2%, and 1 mm/1%) with a threshold of 10%. Dose-volume histogram analysis was used to compare the dose parameters for target volumes, and organs at risk (OARs), such as D98%, D50%, D2%, Dmax, V20, and V5. Monitor units (MUs) and delivery time were also compared. Results: There were significant differences in the three intensity-modulated radiotherapy plans. For target volume, VMAT showed the highest planning target volume (PTV) D98% and the lowest PTV D50% compared with sIMRT or dIMRT. The PTV D2% of VMAT was lower than that of sIMRT and higher than that of dIMRT, and VAMT demonstrated the highest conformity index and MU, lowest homogeneity index, and shortest treatment delivery time. For the OARs, VMAT is not inferior to sIMRT and dIMRT in OARs protection. For the dosimetric verification, the entire area, PTV, lungs, heart, and spinal cord of VMAT showed the highest γ pass rates than the other two techniques under the gamma 3 mm/3% criteria, which was even more pronounced when the stricter gamma criteria of 2 mm/2% and 1 mm/1% were applied. Conclusion: VMAT can be applied to radiotherapy of thymoma, and the accuracy of treatment plan execution can be guaranteed through the ArcCHECK-3DVH system.

Publisher

Medknow

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3