Diagnostic threshold and performance of anion gap in screening for high anion gap metabolic acidosis

Author:

Chionh Chang Yin1,Tien Carolyn Shan-Yeu12, ,Yeon Wenxiang1

Affiliation:

1. Department of Renal Medicine, Changi General Hospital, Singapore

2. Renal Medicine, SingHealth Residency, Singapore

Abstract

Abstract Introduction: The anion gap (AG) is commonly used to screen for acid–base disorders. It was proposed that the cut-off for high anion gap metabolic acidosis (HAGMA) may be lower with current laboratory techniques, although modern laboratory equipment are still calibrated to familiar reference ranges established with earlier techniques. The appropriate cut-off for HAGMA is unclear. This study aimed to assess the performance of AG as a screening test for HAGMA and to determine the optimal diagnostic threshold of AG for HAGMA. Methods: This was a retrospective analysis of a large, anonymised dataset extracted by computerised protocol from 2017 to 2019. All inpatients with blood samples taken for organic acids (lactate, ketone or salicylate) paired with a metabolic panel were included. The target condition was HAGMA secondary to elevated blood lactate, ketone and/or salicylate. Sensitivity for HAGMA was explored at various AG cut-off levels. Results: Of 16,475 patients, 2,621 had organic acidosis. Median age was 65 years, and median estimated glomerular filtration rate was 70 mL/min/1.73 m2. With organic acidosis, the median AG was 23 (interquartile range [IQR] 20–29) mEq/L, while without organic acidosis, the median AG was 16 (IQR 14–19) mEq/L. The area under the curve-receiver operating characteristic of AG for HAGMA was 0.873. Desired sensitivity for HAGMA was set at ≥95%, and this was found with an AG threshold of ≥15 mEq/L (sensitivity 98.1%, specificity 34.0%). Conclusion: The recommended AG threshold value is ≥15 mEq/L with a high sensitivity for HAGMA. The AG should always be interpreted with the clinical context, and it should be repeated as the clinical picture evolves.

Publisher

Medknow

Reference37 articles.

1. Clinical use of the anion gap;Emmett;Medicine (Baltimore),1977

2. The anion gap;Oh;N Engl J Med,1977

3. Anion-gap interpretation: The old and the new;Emmett;Nat Clin Pract Nephrol,2006

4. Disorders associated with an altered anion gap;Gabow;Kidney Int,1985

5. Serum anion gap: Its uses and limitations in clinical medicine;Kraut;Clin J Am Soc Nephrol,2007

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3