An institutional study on accuracy of freehand cervical C1 C2 screws placement by knock and drill technique in craniovertebral anomalous bony anatomy: An evaluation of more than 600 screws based on SGPGI screw accuracy criteria

Author:

Sasapardhi Sudhir Bisan1,Verma Pawan Kumar1,Srivastava Arun Kumar1,Das Kuntal Kanti1,Kumar Ashutosh1,Dikshit Priyadarshi2,Maurya Ved Prakash1,Bhaisora Kamlesh Singh1,Mehrotra Anant1,Jaiswal Awadhesh Kumar1,Mishra Prabhaker3,Behari Sanjay1,Kumar Raj1,Mishra Harshit4,Shahare Kalyani4

Affiliation:

1. Department of Neurosurgery, Sanjay Gandhi Postgraduate Institute of Medical Sciences, Lucknow, Uttar Pradesh, India

2. Department of Neurosurgery, AIIMS, Guwahati, Assam, India

3. Department of Biostatistics and Health Informatics, Sanjay Gandhi Postgraduate Institute of Medical Sciences, Lucknow, Uttar Pradesh, India

4. Department of Neuroanesthesiology, Sanjay Gandhi Postgraduate Institute of Medical Sciences, Lucknow, Uttar Pradesh, India

Abstract

ABSTRACT Purpose: To assess the accuracy of freehand cervical C1 C2 screws placement by knock and drill (K and D) technique in craniovertebral anomalous bony anatomy. Materials and Methods: From January 2017 to December 2022, 682 consecutive C1 C2 screws in 215 patients with craniovertebral junction (CVJ) anomalies were enrolled. All patients underwent posterior fixation with K and D technique without any fluoroscopic guidance. The patient’s demographic details, clinical details, radiological details, major intraoperative events, and postoperative complications were noted. The screws malposition grades and direction on CT images in the axial and sagittal plane were defined as new per proposed “SGPGI accuracy criteria.” All patients had a clinical evaluation at 3-month follow-up. Results: Total 682 C1, C2 screws were placed in 215 patients for CVJ anomalies using K and D technique. The accuracy of screws placement by freehand technique was 84.46% (576/682). So with technique explained the rate of malplacement in simple (16.35%) and complex (15.19%) groups were almost comparable and comparison difference was not significant (P = 0.7005). Conclusion: The freehand technique, as described, is effective in cases of anomalous bony anatomy, and it is mandatory in complex CVJ anomalies. The accuracy of screw placement and VA injury is comparable with major studies. This technique is supposedly cost-effective and less hazardous to both health-care workers and patients.

Publisher

Medknow

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3