Central Vein Stenosis or Occlusion Associated with Cardiac Rhythm Management Device Leads in Hemodialysis Patients with Ipsilateral Arteriovenous Access: A Retrospective Study of Treatment Using Stents or Stent-Grafts

Author:

Saad Theodore F.1,Myers G. Robert2,Cicone Jeffrey1

Affiliation:

1. Nephrology Associates, PA, Newark, DE - USA; Vascular Access Center, Newark, DE - USA; Nephrology, Christiana Care Health System Department of Medicine, Newark, DE - USA

2. Cardiology, Christiana Care Health System Department of Medicine, Newark, DE - USA

Abstract

Purpose Symptomatic central vein stenosis commonly occurs when cardiac rhythm management device (CRMD) leads are placed via the subclavian vein ipsilateral to arteriovenous (AV) hemodialysis (HD) access. The purposes of this study were to determine the outcomes, complications, and patency following stenting of CRMD lead-associated central vein stenosis or occlusion, and to determine the effect of stents on CRMD function. Methods Fourteen HD patients with AV access and an ipsilateral CRMD were treated with stents for symptomatic central vein stenosis or occlusion following inadequate response to angioplasty from January 2005 to December 2009. Subsequent access interventions, complications, and outcomes were reviewed retrospectively. Cardiology records were examined to assess CRMD function. Results Treatment of stenosis or occlusion with angioplasty and stenting resulted in 100% procedural success and no complications. At 6 and 12 months, respectively, primary patency rates were 45.5% and 9.0%; primary-assisted patency rates were 90.9% and 80.0%; secondary patency rates were 100% and 90.0%. There were 42 repeat interventions performed in 12 patients; five received additional stents. The mean number of subsequent interventions was 3.2 per patient (2.1 per patient-year). All CRMD testing demonstrated normal function with no device or lead failure. Seven of the 14 subjects died resulting in a 35.3% annual mortality rate. No deaths were attributable to dysrhythmia or CRMD failure and no patient required CRMD removal or exchange. Conclusions Placement of stents for CRMD lead-associated stenosis or occlusion yields high success and low complication rates with no effect on CRMD function. Patency rates are similar to those reported in other series of central venous stents.

Publisher

SAGE Publications

Subject

Nephrology,Surgery

Cited by 20 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3