Axillary Coverage by Whole Breast Irradiation in 1 to 2 Positive Sentinel Lymph Nodes in Breast Cancer Patients

Author:

De Santis Maria Carmen1,Bonfantini Francesca2,Dispinzieri Michela1,Meroni Silvia2,Diletto Barbara1,Mantero Elisa D.1,Franceschini Marzia1,Soncini Fulvia1,Di Cosimo Serena3,Cosentino Vito2,Pignoli Emanuele2,Lozza Laura1

Affiliation:

1. Radiotherapy Unit 1, National Cancer Institute of Milan, Milan - Italy

2. Medical Physics Unit, National Cancer Institute of Milan, Milan - Italy

3. Oncology Department, National Cancer Institute of Milan, Milan - Italy

Abstract

Purpose To evaluate the dosimetric coverage of axillary levels I, II, and III obtained with standard whole breast irradiation in 1 to 2 positive sentinel lymph nodes (SLNs) patients not submitted to axillary lymph nodes dissection (ALND), and to compare the lymph nodes areas coverage obtained with 3D conformal radiation therapy, intensity-modulated radiotherapy (IMRT), and volumetric modulated arc therapy (VMAT). Methods Patients with 1 to 2 positive SLNs undergoing breast-conserving therapy, without ALND, were included in the analysis. For each patient, 3 treatment plans were performed: a 3D conventional tangential plan, a static IMRT plan, and a volumetric IMRT, designed to encompass the entire breast parenchyma. The volumes of axillary levels I, II, and III receiving 90% and 95% (V90, V95) of the whole breast prescribed dose were evaluated. Dose-volume histograms were compared by means of the Friedman test. Results Ten patients were enrolled. All defined breast volumes received >95% of the prescribed dose with the 3 techniques. Median V95 for axillary level I was 26.4% (range 4.7%-61.3%) for 3D plans, 8.6% (range 0.64%-19.1%) for static IMRT plans, and 2.6% (range 0.4%-4.7%) for volumetric IMRT plans (p<0.001). Median V95 for axillary level II was 5.4% (range 0%-14.6%), 1.9% (range 0%-15%), and 2.6% (range 0.4%-4.7%) for 3D, static IMRT, and volumetric IMRT, respectively (p<0.001). Conclusions Results of our analysis showed that standard 3D tangential whole breast irradiation failed to deliver a therapeutic dose to axillary levels I and II. The coverage was even lower using static and volumetric IMRT techniques.

Publisher

SAGE Publications

Subject

Cancer Research,Oncology,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3