Quantification of Hemodialysis Dose: What Kt/V to Choose?

Author:

Aatif Taoufiq1,Hassani Kawtar1,Alayoud Ahmed1,Zajjari Yassir1,Maoujoud Omar1,Benyahia Mohamed1,Oualim Zouhair1

Affiliation:

1. Department of Nephrology, Dialysis and Renal Transplantation, Mohammed V Military Hospital, Faculty of Medicine, Mohammed V-Souissi University, Rabat - Morocco

Abstract

Background Quantification of hemodialysis became more accurate and easier after the advent of ionic dialysance and the use of methods for estimating urea distribution volume (V). The aim of this study was to compare different methods of hemodialysis dose assessment: Kt/VDau (Daugirdas 2nd generation), Kt/VOCM (Kt by OCM (Online Clearance Monitor) and V by Watson), and Kt/VBCM (Kt by OCM and V by bio-impedance); and to assess the dialysis adequacy, defined by a Kt/V≥1.4. Design Prospective, observational study. Methods 35 hemodialysis sessions were evaluated in 35 chronic hemodialysis patients. During each session, we measured simultaneously, Kt/VOCM, Kt/VBCM and calculated Kt/VDau by performing blood samples before and after each session. Results 35 patients, gender (M/F: 19/16), mean age of 50.49 years, were evaluated. We noted a difference between the three methods of evaluating Kt/V index: Kt/VDau, Kt/VOCM and Kt/VBCM (1.82 ± 0.29; 1.45 ± 0.23; 1.8 ± 0.33, p<0.001). Comparison of Kt/VOCM with Kt/VDau and Kt/VBCM leads to a significant systematic underestimate of Kt/V by 22% and 20.5% respectively. Better agreement between Kt/VDau and Kt/VBCM was observed. The adequate hemodialysis was achieved, according to three methods: Kt/VDau, Kt/VOCM and Kt/VBCM respectively in 100%, 57,1% and 88.6% of the cases. Conclusions The Kt/V index is different depending on the method used for its evaluation. The three methods can be used for quantification of hemodialysis with a better agreement between Kt/VDau and Kt/VBCM. In this study, Kt/VOCM results underestimate hemodialysis efficiency. This difference has to be considered when applying quantification of hemodialysis to clinical practice.

Publisher

SAGE Publications

Subject

Biomedical Engineering,Biomaterials,General Medicine,Medicine (miscellaneous),Bioengineering

Cited by 10 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3