Fluid structure interaction model analysis of cerebrospinal fluid circulation in patients with continuous-flow left ventricular assist devices

Author:

Luc Jessica G.Y.1,Pierre Clifford A.2,Phan Kevin3,Vahedein Yashar S.4,Liberson Alexander S.4,Cornwell William K.5,Phillips Steven J.6,Tchantchaleishvili Vakhtang7

Affiliation:

1. Faculty of Medicine and Dentistry, University of Alberta, Edmonton, AB - Canada

2. Department of Neurosurgery, University of Rochester Medical Center, Rochester, NY - USA

3. Faculty of Medicine, University of Sydney, Sydney - Australia

4. Kate Gleason College of Engineering, Rochester Institute of Technology, Rochester, NY - USA

5. Division of Cardiology, Department of Internal Medicine, University of Colorado Anschutz Medical Campus, Aurora, CO - USA

6. National Library of Medicine, National Institutes of Health, U.S. Department of Health and Human Services, Bethesda, MD - USA

7. Division of Cardiothoracic Surgery, Thomas Jefferson University, Philadelphia, PA - USA

Abstract

Purpose: The current 1-dimensional fluid structure interaction model (FSI) for understanding cerebrospinal fluid (CSF) circulation requires pulsatility as a precondition and has not been applied to patients with continuous-flow left ventricular assist devices (CF-LVAD) where pulsatility is chronically reduced. Our study aims to characterize the behavior of CSF pressure and flow in patients with CF-LVADs using a computational FSI model. Methods: Utilizing the computational FSI model, CSF production in choroid plexuses of the 4 ventricles was specified as a boundary condition for the model. The other source of production from capillary ultrafiltrate spaces was accounted for by the mass conservation equation. The primary CSF absorption sites (i.e., arachnoid granulations) were treated as the outlet boundary conditions. We established a low pulse wave to represent patients with a CF-LVAD. Results: From the model, low pulse conditions resulted in a reduction in CSF pressure amplitude and velocity though the overall flow rate was unchanged. Conclusions: The existing FSI model is not a suitable representation of CSF flow in CF-LVAD patients. More studies are needed to elucidate the role of pulsatility in CSF flow and the compensatory changes in CSF production and absorption that occur in patients with CF-LVADs in whom pulsatility is diminished.

Publisher

SAGE Publications

Subject

Biomedical Engineering,Biomaterials,General Medicine,Medicine (miscellaneous),Bioengineering

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3