Affiliation:
1. Richard Bright Renal Service, Southmead Hospital, North Bristol NHS Trust, Bristol - UK
2. UCL Centre for Nephrology, Royal Free Hospital, London - UK
Abstract
Background Haemodiafiltration (HDF) has been reported to cause less hypotension than haemodialysis (HD). We hypothesized that HDF causes less change in vascular tone, thereby reducing hypotension. Methods Aortic pulse wave velocity (PWVao) was measured in 284 patients, during a single dialysis session using cooled dialysate (117 HD, 177 HDF). Patient groups were matched for age, sex and cardiovascular comorbidity. Results Systolic blood pressure (SBP) declined from 144 ± 26 to 133 ± 26 after 20 minutes, and to 131 ± 26 mmHg post HD, and for HDF from 152 ± 26 to 143 ± 27 after 20 minutes, then to 138 ± 27 mmHg post HDF. Net Ultrafiltration rates to achieve weight loss were similar; HD 0.13 ± 0.06 vs HDF 0.12 ± 0.05 mL/kg/min. PWVao did not change after 20 minutes HD 0.42(-0.7 to 1.3), HDF 0.5 (-0.6 to 1.8) or at the end of the session: HD -0.39 (1.5 to 1.2), HDF-0.41(-2.0 to 1.3) m/s. Aortic augmentation index (AiAxo), assessment of vascular tone fell significantly with both HD; 20 minutes by 6.2 (-2.5 to 14), end 5.6 (-6.7 to 13.9), and HDF 20 min by 4.2 (-2.5 to 10), end 7.8 (-0.8 to 19.3), with no difference between HD and HDF. The ultrafiltration rate correlated with % change in aortic SBP (r = 0.28 p = 0.004), but not with changes in PWVao or augmentation indices. Conclusions Blood pressure declined during both HD and HDF treatments, as did augmentation indices, unrelated to weight loss, suggesting a reduction in vascular stiffness occurs independently of treatment modality. We did not observe an advantage for HDF.
Subject
Biomedical Engineering,Biomaterials,General Medicine,Medicine (miscellaneous),Bioengineering
Cited by
5 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献