Kinematic analysis of new and used reciprocating endodontic motors in 2 different modes

Author:

Irmak Özgür1,Orhan Ekim O.2

Affiliation:

1. Department of Restorative Dentistry, Faculty of Dentistry, Eskişehir Osmangazi University, Eskişehir - Turkey

2. Department of Endodontics, Faculty of Dentistry, Eskişehir Osmangazi University, Eskişehir - Turkey

Abstract

Purpose: The actual reciprocating angles of endodontic motors might differ from the manufacturers’ set values. This study analyzed the effect of clinical usage on the kinematics of reciprocating endodontic motors with 2 different reciprocal modes. Methods: 1 new and 3 used reciprocating endodontic motors (X-Smart Plus, Dentsply Maillefer) with 2 different reciprocating modes, WaveOne mode (W-mode) or Reciproc mode (R-mode), were analyzed. An angle measurement disc was inserted into a contra-angle. Reciprocating motions were recorded with a high-speed camera at 1,200 fps and analyzed on a computer. The following kinematic parameters were calculated: duration of each reciprocating motion, engaging and disengaging angles, cycle rotational speeds, engaging and disengaging rotational speeds, net cycle angle, total cycle angle, and number of cycles to complete full rotation. One-way ANOVA and Kruskal-Wallis test followed by multiple comparison tests were used for statistical analysis (p = 0.05). Results: In W-mode, the actual engaging angles of all used and new motors were different from the manufacturer’s set values (p<0.0001), whereas there was no difference between actual engaging angles among the motors (p>0.05). In R-mode, the actual engaging angles of all used and new motors were similar to the manufacturers’ set values (p>0.05). There was no difference between the actual engaging angles among motors (p>0.05). Both the W-mode and R-mode showed statistically different values of actual disengaging angles for all used and new motors when compared with the manufacturers’ set value (p<0.0001). Conclusions: This study confirmed that the actual kinematics of reciprocating endodontic motors differ from the manufacturers’ set values. Some kinematic parameters were influenced by the clinical usage of the motors.

Publisher

SAGE Publications

Subject

Biomedical Engineering,Biomaterials,General Medicine,Medicine (miscellaneous),Bioengineering

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3