In a Porcine Model of Mixed Acidemia HES 130/0.4 May Support More Stable Hemodynamics during CVVH when Compared to Gelatine

Author:

Keckel Tobias1,Russ Martin12,Bedarf Janis R.1,Ott Sascha1,Hiebl Bernhard3,Haacke Nadine1,Wagner Johanna J.1,Unger Juliane K.1

Affiliation:

1. Department of Experimental Medicine (FEM), Charité - Universitätsmedizin Berlin, Campus Virchow, Berlin - Germany

2. Department of Anesthesiology and Operative Intensive Care Medicine, Charité - Universitätsmedizin Berlin, Campus Virchow and Campus Mitte, Berlin - Germany

3. Center for Medical Basic Research, Martin-Luther-University Halle-Wittenberg, Halle (Saale) - Germany

Abstract

Purpose Continuous veno-venous hemofiltration (CVVH) and mixed acidemia often occur simultaneously in critically ill patients. In a previous study in non-acidemic pigs we found that colloids and CVVH interact specifically with respect to hemodynamic stability, with favorable effects for 6% HES 130/0.4 versus 4% gelatine (GEL) infusion. In a porcine model, we investigated whether these colloid-type associated differences are still dominant under acidemic conditions. Methods We utilized 5 groups, a non-acidemic reference group receiving HES130 and CVVH; two acidemic groups receiving HES130 infusion (one with and one without CVVH); and two acidemic groups receiving GEL infusion (one with and one without CVVH). Mixed acidemia (pH ∼7.20) was established by low tidal volume ventilation and acid infusion. Stable acidemia/CVVH application was maintained for 3 hours. Hemodynamics and blood gases were recorded. Results Mixed acidemia led to a significant decrease in MAP and increase in MPAP in all groups. CVVH led to a further decrease in MAP but improved MPAP. During CVVH, HES130 ensured significantly higher MAP, Hb, and DO2 values than GEL infusion. In the groups without CVVH these differences between HES 130/0.4 and GEL were not observed. Conclusions As in a previous study in non-acidemic pigs, we found a colloid-specific influence of HES130 versus GEL on hemodynamics during CVVH under acidemia. Again, HES130 infusion may lead to favorable effects. In contrast, acidemia without CVVH application was dominant over the impact of a respective colloid. The application of a CVVH seems to be an important trigger for the overall circulatory response to a particular colloid.

Publisher

SAGE Publications

Subject

Biomedical Engineering,Biomaterials,General Medicine,Medicine (miscellaneous),Bioengineering

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3