Evaluation of a Polynephron Dialysis Membrane considering New Aspects of Biocompatibility

Author:

Martínez-Miguel Patricia12,de Sequera Patricia3,Albalate Marta3,Medrano Diana2,Sánchez-Villanueva Rafael4,Molina Alvaro5,Sousa Fernando6,Benito Jesús7,Nuñez Jesús8,Vozmediano Carmen9,Aragoncillo Inés10,Barril Guillermina11,Rodríguez-Puyol Diego12,Pérez-García Rafael3,López-Ongil Susana2

Affiliation:

1. Nephrology Section, Foundation for Biomedical Research, Príncipe de Asturias Hospital, Alcalá de Henares, Madrid - Spain

2. Research Unit, Foundation for Biomedical Research, Príncipe de Asturias Hospital, Alcalá de Henares, Madrid - Spain

3. Nephrology Section, Infanta Leonor Hospital, Vallecas, Madrid - Spain

4. Nephrology Section, La Paz Hospital, Madrid - Spain

5. Nephrology Section, Segovia Hospital Complex, Segovia - Spain

6. Nephrology Section, Río Carrión Hospital, Palencia - Spain

7. Nephrology Section, Infanta Cristina Hospital, Madrid - Spain

8. Nephrology Section, Valladolid Hospital, Valladolid - Spain

9. Nephrology Section, Ciudad Real General Hospital, Ciudad Real - Spain

10. Nephrology Section, Infanta Sofía Hospital, Madrid - Spain

11. Nephrology Section, La Princesa Hospital, Madrid - Spain

Abstract

Purpose The biocompatibility of dialyzers may influence the inflammatory state of hemodialysis patients. This study compares the effect of a high-flux polynephron membrane with other high-flux membranes, helixone and polyamide, on some inflammation biomarkers based on the analysis of circulating mononuclear cells (MC). Methods The study included 47 patients on hemodialysis with helixone and polyamide; 9 formed the control group, without changes in their dialyzers throughout the study, and 38 formed the intervention group, in which their dialyzers were replaced by polynephron. In both groups, blood samples were taken at the beginning of the study before and after hemodialysis session, and at the end of the study 4 months later. In each extraction, biochemical parameters were determined, and MC isolated using Ficoll gradient. Production of reactive oxygen species and the percentage of activated MC (CD14+CD16+) were measured by flow cytometry, and protein levels of heat-shock proteins (Hsp70/Hsp90) studied by Western blot. Results After 1 hemodialysis session with different membranes, no significant differences were observed in the different parameters considered. After 4 months of dialysis with polynephron, a significant reduction in the percentage of CD14+CD16+ and in the β2-microglobulin reduction ratio were found, with respect to helixone and polyamide, without changes in the other parameters analyzed. Conclusions The use of polynephron for 4 months reduces the percentage of CD14+CD16+ compared to helixone and polyamide, suggesting a better profile regarding activation of the inflammatory response. These findings could be explained by a better biocompatibility or an increased reduction of medium-sized toxic molecules.

Publisher

SAGE Publications

Subject

Biomedical Engineering,Biomaterials,General Medicine,Medicine (miscellaneous),Bioengineering

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3