In vitro Study of a Standardized Approach to Aortic Cusp Extension

Author:

Vismara Riccardo12,Leopaldi Alberto M.12,Romagnoni Claudia32,Contino Monica32,Mangini Andrea132,Stevanella Marco12,Fiore Gianfranco B.12,Antona Carlo32

Affiliation:

1. Department of Electronic, Information and Bioengineering, Politecnico di Milano, Milan - Italy

2. For Cardio Lab, Università di Milano - Politecnico di Milano, Milan - Italy

3. Cardiovascular Surgery Department, Luigi Sacco University General Hospital, Milan - Italy

Abstract

Purpose Cusp extension technique (CET) is a reparative surgical procedure for restoring aortic valve function by suturing patches to the compromised native leaflets. Its outcomes are strongly dependent on the ability of the surgeon. We proposed and tested a novel approach on an in vitro model, aimed at standardizing and simplifying the surgical procedure. Methods A set of standard pre-cut bovine pericardium patches, available in different sizes, was developed. The surgeon can choose the leaflet-specific patches to be implanted according to the patient anatomy, using a geometrical model of the aortic valve whose inputs are the measured intercommissural distances. The hemodynamic performance of this approach was evaluated on porcine aortic roots in a pulsatile mock loop. Hydrodynamic and kinematic evaluation of the samples was provided. Results After CET, mean and maximum pressure drops were 3.1 ± 1.3 mmHg and 25.4 ± 5.0 mmHg respectively, and EOA was 3.8 ± 0.8 cm2. Static regurgitant fraction and closing volumes were 6.9 ± 2.7% and 7.0 ± 1.5 mL, respectively. All the hemodynamics changes induced by the surgery were statistically significant yet clinically irrelevant as compared to baseline. The treatment also induced a statistically significant alteration in the closing time of the valve. Conclusions Our approach to cusp extension proved to be reliable and effective in restoring valve functioning, without significantly altering the physiological kinematics. The use of pre-cut patches considerably simplified the surgery, increasing standardization and repeatability.

Publisher

SAGE Publications

Subject

Biomedical Engineering,Biomaterials,General Medicine,Medicine (miscellaneous),Bioengineering

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3