Affiliation:
1. Joint Replacement Institute, St. Vincent Medical Center, Los Angeles - USA
Abstract
Second-generation metal-on-metal total hip arthroplasty (THA) was introduced in the early 1990s to address osteolysis and aseptic loosening resulting from polyethylene wear. We present a comparison between the Transcend metal-on-metal and Interseal metal-on-polyethylene THAs. Thirty-seven hips with Transcend metal bearings and 36 hips with Interseal polyethylene acetabular liners but identical acetabular shells were reviewed to determine clinical performance, radiographic changes, and survivorship. Patients with higher anticipated activity levels were selected to receive the Transcend bearing. Mean follow-up time was 107.0 months for the Transcend group, and 90.4 months for the Interseal group. There were no significant differences between the Transcend and Interseal groups for mode of failure and survivorship, which is notable considering the younger and more active Transcend group. However, the Transcend group showed significantly better clinical scores, which may have been a result of the selection methods. Neither surface was differentially implicated in osteolysis, aseptic loosening, or adverse local tissue reaction (ALTR). Our study shows a favorable and comparable performance for both systems.
Subject
Orthopedics and Sports Medicine,Surgery
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献