Periacetabular Osteotomy: Validation of Intraoperative Fluoroscopic Monitoring of Acetabular Orientation

Author:

Kühnel Stefanie P.1,Kalberer Fabian A.2,Dora Claudio F.3

Affiliation:

1. Department of Orthopaedics, University of Zurich, Uniklinik Balgrist, 8008 Zurich - Switzerland

2. Department of Orthopaedics, Kantonsspital, 8401 Winterthur - Switzerland

3. Head of Hip and Pelvis, Department of Orthopedics, University of Zurich, Uniklinik Balgrist, 8008 Zurich - Switzerland

Abstract

During periacetabular osteotomy (PAO) the acetabulum is reorientated and the correction monitored by one or more anteroposterior pelvic radiographs. Obtaining these images is time consuming and requires additional technical and personal resources. Such disadvantages could be overcome with the use of fluoroscopy. However, information obtained from fluoroscopy should have the same quality when compared to standard pelvic radiography. Our purpose was to define a suitable fluoroscopy setup and compare the information obtained from the fluoroscopic images to that obtained from a traditional anteroposterior pelvic radiograph. In a consecutive series of 22 patients the acetabular fragment was monitored by a defined intraoperative fluoroscopy setup in addition to a pelvic radiograph. The images were analyzed in random order utilizing common parameters to judge the quality of acetabular orientation. Agreement between the two images was assessed using kappa statistics and compared to the intra-observer reliability obtained from an independent experienced hip surgeon reading the same set of pelvic radiographs on two occasions. In 5 patients the radiation exposure during both fluoroscopy and standard AP pelvic radiography was measured and compared. Agreement of angular measurements of acetabular coverage and version as well as qualitative parameters of acetabular orientation and position between fluoroscopy and pelvic radiographs was at least equal to the intra-observer agreement of an independent experienced hip surgeon reviewing the pelvic radiographs alone. Significantly less radiation exposure was recorded with the use of fluoroscopy when compared to traditional pelvic radiography. We conclude that the use of intraoperative pelvic radiographs during PAO procedures can be replaced by fluoroscopy without quality impairment.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine,Surgery

Cited by 12 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3