Evaluation of Tubular Poly(Trimethylene Carbonate) Tissue Engineering Scaffolds in a Circulating Pulsatile Flow System

Author:

Song Yan1,Wennink Jos W.H.1,Poot Andre A.1,Vermes Istvan12,Feijen Jan1,Grijpma Dirk W.13

Affiliation:

1. Institute for Biomedical Technology (BMTI) and Department of Polymer Chemistry and Biomaterials, Faculty of Science and Technology, University of Twente, Enschede - The Netherlands

2. Department of Clinical Chemistry, Medical Spectrum Twente Hospital, Enschede - The Netherlands

3. Department of Biomedical Engineering, University Medical Center Groningen, University of Groningen, Groningen - The Netherlands

Abstract

Tubular scaffolds (internal diameter approximately 3 mm and wall thickness approximately 0.8 mm) with a porosity of approximately 83% and an average pore size of 116 μm were prepared from flexible poly(trimethylene carbonate) (PTMC) polymer by dip-coating and particulate leaching methods. PTMC is a flexible and biocompatible polymer that crosslinks upon irradiation; porous network structures were obtained by irradiating the specimens in vacuum at 25 kGy before leaching soluble salt particles. To assess the suitability of these scaffolds in dynamic cell culturing for cardiovascular tissue engineering, the scaffolds were coated with a thin (0.1 to 0.2 mm) non-porous PTMC layer and its performance was evaluated in a closed pulsatile flow system (PFS). For this, the PFS was operated at physiological conditions at liquid flows of 1.56 ml/s with pressures varying from 80–120 mmHg at a frequency of 70 pulsations per minute. The mechanical properties of these coated porous PTMC scaffolds were not significantly different than non-coated scaffolds. Typical tensile strengths in the radial direction were 0.15 MPa, initial stiffness values were close to 1.4 MPa. Their creep resistance in cyclic deformation experiments was excellent. In the pulsatile flow setup, the distention rates of these flexible and elastic scaffolds were approximately 0.10% per mmHg, which is comparable to that of a porcine carotid artery (0.11% per mmHg). The compliance and stiffness index values were close to those of natural arteries. In long-term deformation studies, where the scaffolds were subjected to physiological pulsatile pressures for one week, the morphology and mechanical properties of the PTMC scaffolds did not change. This suggests their suitability for application in a dynamic cell culture bioreactor.

Publisher

SAGE Publications

Subject

Biomedical Engineering,Biomaterials,General Medicine,Medicine (miscellaneous),Bioengineering

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3