A comparative study of the visual outcomes between a new trifocal and an extended depth of focus intraocular lens

Author:

Ruiz-Mesa Ramón1,Abengózar-Vela Antonio1,Ruiz-Santos María1

Affiliation:

1. Oftalvist CIO Jerez, Puerta del Sur Hospital, Cádiz - Spain

Abstract

Purpose: To evaluate and compare the visual outcomes and ocular optical performance of the PanOptix trifocal intraocular lens (IOL) and Symfony extended range of vision IOL. Methods: Sixty-eight eyes of 34 patients were divided into 2 groups: 20 patients with the PanOptix IOL and 14 patients with the Symfony IOL. Binocular uncorrected distance visual acuity, best-corrected distance visual acuity (BCDVA), distance-corrected intermediate visual acuity (DCIVA) at 80 and 60 cm, and distance-corrected near visual acuity (DCNVA) at 40 cm were evaluated. Additionally, preferred reading distance with best-corrected distance and visual acuity at that distance, binocular defocus curves, mesopic and photopic contrast sensitivity, photic phenomena, and monocular total higher order aberrations (HOAs) were also measured. Results: The visual outcomes for PanOptix and Symfony IOL groups, respectively, were as follows: BCDVA: -0.03 ± 0.03 and -0.02 ± 0.03 logMAR; DCIVA at 80 cm: 0.06 ± 0.06 and 0.06 ± 0.04 logMAR; DCIVA at 60 cm: 0.06 ± 0.10 and 0.05 ± 0.04 logMAR; DCNVA: 0.04 ± 0.06 and 0.20 ± 0.07 logMAR (p<0.001). Similar preferred reading distances were found for both groups (37.0 ± 4.6 and 38.9 ± 5.7 cm, respectively). The visual acuities at those distances were 0.09 ± 0.08 and 0.19 ± 0.08 logMAR (p<0.001), respectively. The defocus curves showed significantly better outcomes for the PanOptix IOL from -2.0 to -4.0 D (p<0.001). No significant differences were found for contrast sensitivity, halometry, or HOAs between the groups. Conclusions: The PanOptix and Symfony IOLs showed comparable visual performance at distance and intermediate. However, the PanOptix IOL provided better near and preferred reading distance VAs and showed a more continuous range of vision than the Symfony IOL.

Publisher

SAGE Publications

Subject

Ophthalmology,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3