Comparative study of 3 exophthalmometers and computed tomographic biometry

Author:

Delmas Juliette1,Loustau Jean-Marie2,Martin Sylvain3,Bourmault Loïc1,Adenis Jean-Paul1,Robert Pierre-Yves1

Affiliation:

1. Department of Ophthalmology, Limoges Hospital, Limoges - France

2. Department of Radiology, Dubois Hospital, Brive - France

3. Department of Radiology, Limoges Hospital, Limoges - France

Abstract

Purpose: Accurate and reproducible exophthalmometry is mandatory to diagnose and follow-up orbital patients, especially in Graves disease. However, many variations are described among the different commercially available exophthalmometers. Methods: Sixty patients, who underwent a cerebral computed tomography (CT) scan, were included. External prebicanthal segments (EPBCS) for right and left eyes (RE and LE), interorbital distance, and globe axial length were recorded by a first observer (O1), more experienced than a second (O2). Intraobserver and interobserver reproducibility were evaluated, using intraclass correlation coefficient (ICC) and Bland and Altman plots. Results: Concordance between each EPBCS measurement for each eye and CT scan biometry was moderate for the Luedde ruler for the 2 observers. For the Hertel exophthalmometer, concordance was moderate for O1 in the 2 eyes and moderate in RE but good in LE for O2. For the Mourits exophthalmometer, this concordance was very good in RE and good in LE for O1, and good whatever the eye for O2. Intraobserver (ICC varying from 0.75 to 0.95 for the 2 observers) and interobserver (ICC from 0.69 to 0.94) reproducibility were high, especially for the Mourits exophthalmometer. Bland and Altman plots showed underestimations when using the Luedde ruler, overestimations when using the Hertel exophthalmometer, and overestimation of small values and underestimation of high values when using the Mourits exophthalmometer when compared to CT scan biometry. Conclusions: We demonstrated great accuracy to CT scan biometry with 1-prism Mourits exophthalmometer, low accuracy with the Luedde instrument, and intermediate accuracy with the Hertel exophthalmometer, with fair intraobserver and interobserver reproducibility.

Publisher

SAGE Publications

Subject

Ophthalmology,General Medicine

Cited by 14 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3