Affiliation:
1. Department of Orthopaedics, Southern General Hospital, Glasgow - UK
Abstract
The ‘cement in cement’ technique for revision hip arthroplasty has become popular in recent years, particularly in relation to polished taper stems. Since 2006 a short Exeter stem with 44mm offset has been available specifically for this purpose. We report a fracture of such a stem in the absence of trauma 5 years after the revision procedure. The patient had a BMI of 27.8 and the proximal cement mantle gave good support to the stem. The fracture initiated and propagated from the introducer hole on the shoulder of the prosthesis. Macroscopically there was no defect in this area. This may be an unusual case of fatigue failure.
Subject
Orthopedics and Sports Medicine,Surgery
Cited by
18 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献