Metal Ion Interpretation in Resurfacing versus Conventional Hip Arthroplasty and in Whole Blood versus Serum. How should we Interpret Metal Ion Data?

Author:

Smolders José M.H.1,Bisseling Pepijn1,Hol Annemiek1,Van Der Straeten Catherine2,Schreurs B. Willem3,Van Susante Job L.C.1

Affiliation:

1. Department of Orthopaedics, Rijnstate Hospital, Arnhem - The Netherlands

2. Independent Consultant Clinical Research, Ghent - Belgium

3. Department of Orthopaedics, Radboud University Nijmegen Medical Centre - The Netherlands

Abstract

Metal ions generated from joint replacements are a cause for concern. There is no consensus on the best surrogate measure of metal ion exposure, and both serum and whole blood measurements are used in clinical practice. This study provides a guideline for interpretation of metal ion analysis in clinical practice. In a prospective trial comparing hip resurfacing (HR) with a conventional metal-on-metal (MoM) total hip arthroplasty (THA) cobalt and chromium levels were determined for whole blood and serum in 343 paired samples at regular intervals up to 24 months postoperatively. Cobalt whole blood and serum levels increased significantly after both procedures. Cobalt concentrations were significantly higher for the HR group compared to the THA group, at 3, 6 and 12 months, for whole blood and serum. At 24 months cobalt levels decreased and differences between HR and THA were no longer significant. In contrast, chromium whole blood levels remained significantly higher for HR until 24 months. Whole blood and serum levels could not be used interchangeably. The mean differences for cobalt and chromium between blood and serum values were +0.13 μg/L and –0.91 μg/L respectively. Regression analysis provided a formula for conversion from serum to blood of 0.34+[0.88*Co serum] for cobalt and 0.14+[0.58*Cr serum] for chromium, with an acceptable prediction error below ±1.0 μg/L. Cobalt and chromium levels were significantly higher for HR versus THA, especially during the run-in phase of one year. Overall, the metal ion levels were well below 5 μg/L. We cannot recommend the use of whole blood over serum measurements or vice versa. The provided conversion formula between whole blood and serum in combination with the presented practical guidelines may be useful for clinical practice.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine,Surgery

Cited by 44 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3