3-Year Follow-up of a Long-Term Registry-Based Multicentre Study on Vitamin E Diffused Polyethylene in Total Hip Replacement

Author:

Sillesen Nanna H.1,Greene Meridith E.1,Nebergall Audrey K.1,Huddleston James I.2,Emerson Roger3,Gebuhr Peter4,Troelsen Anders4,Malchau Henrik1

Affiliation:

1. Harris Orthopaedic Laboratory, Massachusetts General Hospital, Boston - USA

2. Department of Orthopaedic Surgery, Stanford University Medical Center, Stanford - USA

3. Texas center for Joint Replacement, Plano, Texas - USA

4. Department of Orthopaedics, Clinical Orthopedic Research Hvidovre, Copenhagen University Hospital Hvidovre, Hvidovre - Denmark

Abstract

Purpose Preclinical studies of vitamin E diffused highly cross-linked polyethylene (E-XLPE) has shown enhanced mechanical properties with less wear. The purpose of our study was to document the early clinical outcome of E-XLPE to ensure, for the safety of patients, that there are no unforeseen early adverse events from using this new biomaterial. Methods The enrolled patients (n = 977) have received either a porous titanium coated or porous plasma sprayed acetabular shell with either a E-XLPE liner or a medium cross-linked (AXL) liner. At each follow-up 5 patient-reported outcome measures (PROMs) were completed: Harris Hip Score, Case Mix Indicator, UCLA Activity Score, SF-36, and EQ-5D. Radiographs were measured for cup and stem position, as well as femoral head penetration into the liner (wear). Postoperative complications and revisions were collected. Results At 3 years follow-up, there were 13 revisions due to: 4 periprosthetic fractures; 1 sepsis; 6 instabilities; and 2 implant mismatches at surgery. Wear of the hip implant, calculated by software analysis of pelvis x-rays, from the postoperative interval to 3 years showed a liner penetration rate of 0.027 mm/year for AXL and 0.005 mm/year for E-XLPE with no significant difference between the 2 (p = 0.24). Improvement was seen in all PROMs from the preoperative interval to 3 years after surgery (p<0.0001). Conclusions Early follow-up of the E-XLPE and AXL liners show low penetration. PROMs indicate improvement after total hip arthroplasty in functionality and quality of life across the centers. We have not observed any early in vivo adverse effects from diffusing the liners with vitamin E. Trial registration ClinicalTrials.gov Identifier: NCT00545285.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3