The Ocular Biometric Differences of Diabetic Patients

Author:

Kocatürk Tolga1,Zengin Mehmet Özgür2,Çakmak Harun1,Evliçoğlu Gökhan Evren1,Dündar Sema Oruç1,Ömürlü İmran Kurt3,Ünübol Mustafa4,Güney Engin4

Affiliation:

1. Department of Ophthalmology, Faculty of Medicine, Adnan Menderes University, Aydın - Turkey

2. Department of Ophthalmology, Faculty of Medicine, İzmir University, Medical Park Hospital, İzmir - Turkey

3. Department of Biostatistics, Faculty of Medicine, Adnan Menderes University, Aydın - Turkey

4. Department of Internal Medicine, Endocrinology Division, Faculty of Medicine, Adnan Menderes University, Aydın - Turkey

Abstract

Purpose To investigate the differences in ocular biometric and keratometric characteristics in comparison with biometric measurements using the noncontact optical low coherence reflectometer (OLCR) (Lenstar LS 900, Haag-Streit) on diabetic patients. Methods The eyes of 170 patients were included in this study, including 81 diabetic and 89 nondiabetic subjects. Optical biometric measurements of diabetic and nondiabetic patients (between the ages of 25 and 85 years) who applied to the ophthalmology clinic were noted from March to June 2013. Detailed ophthalmologic examinations were done for every subject. Biometric measurements were done using the noncontact OLCR device. Results Patient age ranged from 29 to 83 years. Subgroup analyses were done in diabetic patients according to their Hba1C levels. The minimum Hba1C value was 5.3, maximum was 12.4, and mean was 7.56 ± 1.48. The median duration of diabetes was 5 years (25th-75th percentile 3.00-11.75). Diabetic patients were found to have thicker lens and shallower anterior chamber in both eyes compared to nondiabetic control subjects. There were no statistical differences between the groups according to central corneal thickness, axial length, or keratometric values in both eyes. However, lens thicknesses were found to be thicker and anterior chamber depth values were found to be shallower in the diabetic group in both eyes. Conclusions It may useful to determine eyeglasses prescription, refractive surgery calculation, lens selection, and previous cataract surgery according to biometric measurements after the regulation of blood glucose.

Publisher

SAGE Publications

Subject

Ophthalmology,General Medicine

Cited by 8 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3