In Vivo Intraocular Pressure Monitoring during Microincision Vitrectomy with and without Active Control of Infusion Pressure

Author:

Yang Hyun S.1,Yun Young I.2,Park Jong H.1,Choi Sangkyung3,Woo Je M.4

Affiliation:

1. Department of Ophthalmology, Seoul Shinsegae Eye Center, Eui Jung Bu, Gyeonggi-do - South Korea

2. College of Medicine, Seoul National University, Seoul - South Korea

3. Department of Ophthalmology, Veterans Health Service Medical Center, Seoul - South Korea

4. Department of Ophthalmology, University of Ulsan, College of Medicine, Ulsan University Hospital, Ulsan - South Korea

Abstract

Purpose To evaluate intraocular pressure (IOP) fluctuation during vitrectomy, we directly monitored IOP in vivo using 2 vitrectomy machines with or without constant infusion pressure monitoring and control. Methods Among 61 eyes of 61 consecutive patients, 32 were assigned to the Accurus system (group 1) and 29 were assigned to the Constellation system (group 2) in this prospective case series. The IOP fluctuations were evaluated during routine vitrectomy procedures. Results The initial IOP before vitrectomy was 20.3 ± 2.4 mm Hg in group 1 using a conventional vented gas forced infusion system and 20.0 ± 0.0 mm Hg in group 2 using active IOP control at 20 mm Hg (p = 0.532). However, the average IOP change during core vitrectomy was -8.6 ± 4.3 mm Hg in group 1 and -0.8 ± 1.1 in group 2 (p<00.001). Maximum IOP was significantly decreased in group 1 (-17.0 ± 2.6 mm Hg) compared with that in group 2 (-4.1 ± 2.2 mm Hg) (p<00.001). Partial ocular collapse was observed during vitrectomy only in group 1 (78.1%). Peak IOP significantly increased during scleral compression and gas and fluid injection but was not significantly different between the groups (all p≥0.147). The IOP fluctuation range was 50-70 mm Hg in both groups. Conclusions The IOP fluctuated significantly during routine vitrectomy using both systems. Hypotony and partial ocular collapse were more frequently observed during vitrectomy with the Accurus system than with the Constellation system. Both systems were vulnerable to IOP surge during indentation and intravitreal injection.

Publisher

SAGE Publications

Subject

Ophthalmology,General Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3