Fractures of Totally Implantable Central venous Ports: More than Fortuity. A Three-Year Single Center Experience

Author:

Balsorano Paolo1,Galducci Giulia1,De Fanti Ilaria1,Evans Samuel Kagan2,De Gaudio Angelo Raffaele1,Pelagatti Cecilia3

Affiliation:

1. Department of Health Science, Section of Anaesthesiology, Intensive Care and Pain Medicine, AOUC Careggi, Florence - Italy

2. Department of Pulmonary and Critical Care Medicine, Rode Island Hospital, Providence, RI - USA

3. Department of Oncology, Section of Anesthesiology and Intensive Care, AOUC Careggi, Florence - Italy

Abstract

Purpose Totally implantable venous access devices (Ports) represent the mainstay for infusion therapy in patients undergoing chemotherapy, total parenteral nutrition and/or long-term antibiotic treatment. Amongst mechanical complications, lesions of the catheter wall represent a rare but potentially severe condition. We report our experience with the accidental detection of catheter ruptures in a series of ports removed for complication or for end of use. Methods All ports removed from January 2011 to June 2013 were considered. All removed ports had been inserted according to a standardized protocol including ultrasound-guided percutaneous venipuncture (out-of-plane or in-plane approaches) and electrocardiogram-guided positioning of the tip. Once removed, each catheter was checked by inspection and saline instillation in order to evaluate the integrity of the device itself and rule out possible ruptures. Results In over 338 removed ports, 12 Groshong catheters out of 65 (18.5%) had evidence of partial rupture of the catheter wall. Amongst considered variables, “out-of-plane” approach and type of port (silicon, closed tip with Groshong valve) were the only ones significantly associated with catheter ruptures (p=0.0003 and 0.0008, respectively). We could detect no evidence of rupture in any silicon open-ended catheter (Celsite ports) or in any catheter inserted by “in-plane” approach to the vein. Conclusions The actual advantage of using port connected with Groshong silicon catheters should be questioned, since apparently they are more fragile than standard catheters. Furthermore, ultrasound-guided “out-of-plane” puncture of the internal jugular vein should be discouraged.

Publisher

SAGE Publications

Subject

Nephrology,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3