Stenoses in the surgically manipulated segment have better angioplasty response compared to the surgically naive segment in fistulas

Author:

Cui Jie12,Xu Dihua1,Ma Jie3,Liu Bingyan3,Kawai Tatsuo4,Yeh Heidi4,Schainfeld Robert5,Irani Zubin2

Affiliation:

1. Division of Nephrology, Department of Medicine, Massachusetts General Hospital, Boston, MA - USA

2. Division of Interventional Radiology, Department of Radiology, Massachusetts General Hospital, Boston, MA - USA

3. Division of Nephrology, Department of Medicine, Peking Union Medical College Hospital, Beijing - China

4. Division of Transplant Surgery, Department of Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA - USA

5. Division of Cardiology, Department of Medicine, Massachusetts General Hospital, Harvard Medical School, Boston, MA - USA

Abstract

Purpose Balloon angioplasty is the standard treatment for dysfunctional hemodialysis fistulas, but angioplasty response of stenotic lesions located in different segments of the dialysis circuit has not been explicitly evaluated. The purpose of this study is to describe the distribution of stenotic lesions in the most common types of arteriovenous fistulas and to investigate the response to balloon angioplasty of stenotic lesions located in various segments of the fistula circuit. Materials and Methods This single-center, retrospective study was approved by the Institutional Review Board. A total of 263 fistulograms performed between January, 2014 and June, 2015 were reviewed. Stenotic lesion response to angioplasty was analyzed based on lesion location using a Kaplan-Meier analysis. Results Juxta-anastomotic stenoses (48%) were the most common lesions in radiocephalic fistulas, while the cephalic arch (30%) and venous outflow tract (24%) were the most common locations of stenotic lesions in brachiocephalic fistulas and basilic vein transposition fistulas, respectively. Primary patency after balloon angioplasty was significantly higher in lesions located in the venous segments manipulated during surgeries compared to the lesions located in the surgically naive zone (p = 0.001). The 6-month and 12-month primary patency of lesions post-angioplasty in the surgical zone were 76% and 71% compared to 58% and 43% in the surgically naive segments. Conclusions The distribution of stenotic lesions differs among each type of fistula. The primary patency of balloon angioplasty of stenotic lesions located in the surgically manipulated venous segment was significantly better than lesions located in the rest of the fistula circuit.

Publisher

SAGE Publications

Subject

Nephrology,Surgery

Cited by 11 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3