Volume Blood Flow, Static Pressure Ratio and Venous Conductance in Native Arterio-venous Fistulae: Three Surveillance Methods Compared

Author:

King David H.1,Paulson William D.2,Al-Qaisi Mo1,Taylor Michael G.3,Panayiotopoulos Yiannis1,Abeygunarsekara Sumith1,Chan Anthony1,Ali Galil1,Chemla Eric S.4

Affiliation:

1. Renal Unit, Broomfield Hospital, Chelmsford, Essex- UK

2. Department of Medicine, Regents University, Augusta, GA - USA

3. Division of Imaging and Radiological Sciences, Kings College, London - UK

4. Division of Medicine and Cardiovascular Sciences, St Georges Vascular Institute, London - UK

Abstract

Purpose Dialysis venous pressure monitoring has been widely recommended as a surveillance method but has not been shown to improve access outcomes in randomised controlled trials. The method has been impaired by the need to either turn off the blood pump or to derive the static venous pressure from the venous pressure measured with the dialysis pump running. We have developed a unique algorithm which converts Doppler-shifted spectral information derived from unsealed pulsatile blood flow waveforms into an estimate of mean blood pressure (MBP) at the point of ultrasound insonation. Methods We have devised the unique expression shown here: MBP = MAP/(1 + Pff/Vff) where MAP is the mean arterial pressure, Pff = (systolic – diastolic)/MAP measured on the contralateral arm and Vff = spectral maximum – minimum/mean. Venous conductance (VC) can be measured by combining this pressure data with Duplex ultrasound blood flow data. A new device BlueDop™ has been used to illustrate the potential clinical value of non-invasive static pressure ratio (SPRn) in a monitoring role. Duplex and BlueDop™ technology were tested in an arterio-venous fistula (AVF) study in which VC, Q and SPRn were compared. Thresholds used for detection of ≥60% venous stenosis were VC <10 mL min−1 mm Hg−1, Q <500 mL min−1, SPRn >0.56. Results The following accuracy was achieved: VC = 96%, Q = 92%, SPRn = 76% with similar accuracy in predicting premature thrombosis. Conclusions A new algorithm has been described and its in vivo accuracy in estimating mean ‘pressure from flow’ has been confirmed. Two new variables and a new dedicated instrument BlueDop™ have been demonstrated in clinical use.

Publisher

SAGE Publications

Subject

Nephrology,Surgery

Cited by 8 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3